2-11
※
5 Service Menu
※
5-1 Trip Chart
※
5-2 Trip Report
※
5-3 PTI History
※
5-4 Alarm Record
※
5-5 Automatic Pumpdown
※
5-6 Monitoring Log (Start, Stop)
※
5-1 Trip Chart
The Trip Chart displays the trip data for up to 90 days
starting from the present in a graphic form. (Fig. 1)
Temperature range is 35
℃
to -40
℃
, Date span is 6
Week.
Press
key to scroll for the past data.
Zoom in/Zoom out function
Press MENU key, then Zoom in/Zoom out screen
appears. (Fig.2)
<
Horizontal axis: Number of days
>
(Default) Zooming in or out from 6 weeks to 10 days, 5
days, 2.5 days, 1 day or vice versa (by
keys).
<
Vertical axis: Temperature
>
(Default) Zooming in or out from 75
℃
(35 to -40
℃
) to
30
℃
, 20
℃
, 10
℃
, 4
℃
or vice versa (by
keys).
Zoom in example
Fig. 3 shows an example of zooming in the circled area
in the Fig. 1. (Date span: 5 Day, Temperature range: 20
℃
)
The procedure follows.
1. Scroll the span until the 25DEC, the day before the
circled portion, appears at the right end on the screen
by pressing
key.
2. Press MENU key to show the Zoom in/Zoom out
screen.
3. Zoom in the Date span from 6 Week into 5 Day.
3-1. Press
key to zoom in the Day span from 6 Week
into 10 Day and press
key.
3-2. Press MENU key again to show the Zoom in/ Zoom out screen, then zoom in from 10 Day to 5 Day
using
key, then press
key.
4. Zoom in the temperature range from 35 to -40
℃
to 10
℃
.
Simular to the Date span, press MENU,
,
key in the following order: 35 to 40
℃
⇒
30
℃
⇒
20
℃⇒
10
℃
.
Service Menu
Trip Report
PTI Data
Alarm Record
Auto Pumpdown
Monitoring log
Trip Chart
Zoom in or out
for date
Zoom in or out
for Temperature
PREV
℃
30.0
0.0
-40.0
25
4
SP
(5.0
℃
) DSS DRS
27
Trip Chart (6Week)
NOV
18
11
21
2010
Sub Menu
Zoom in
Zoom out
(
Temp
)
Zoom out
(
Date
)
(
Date
)
Zoom in
(
Temp
)
T
X
E
N
V
E
R
P
℃
10.0
5.0
-10.0
25
22
SP
(5.0
℃
) DSS DRS
Trip Chart (5 days)
DEC
24
23
2010
PREV
NEXT
20
21
Fig. 1 Initial screen
Fig. 2
Fig. 3
℃
30.0
0.0
-40.0
15
25
SP
(0.0
℃
) DSS DRS
18
PREV
Trip Chart (6Week)
DEC
8
1
11
2011
Zoom in example
(See below.)
Summary of Contents for LX10F10A