background image

3

English

NAME OF PARTS

 Refer to figure 1 on page [1] 

1.

Air outlet (Field supply)

2.

Exhaust duct (Field supply)

3.

Drain pipe

4.

Connection piping

5.

Transmission wiring

6.

Remote controller

 

(Field supply)

7.

Drain discharge device (built-in)
Discharges indoor moisture removed during cooling
operation.

8.

Power line

9.

Ground wiring
This wire releases electricity from the indoor unit to
the ground in order to prevent electric shock or fire.

10.

Air filter (inside filter chamber)

 

(Field supply)

11.

Suction filter chamber

 

(Field supply)

12.

Suction duct (Field supply)

13.

Machine nameplate
The nameplate is imprinted with the machine name 
and specifications.

14.

Suction grille (Field supply)

MAINTENANCE

WARNING

• Only a qualified person is allowed to perform mainte-

nance without daily maintenance.

• Before touching any of connection wirings, be sure to 

turn off all power supply switches.

• Do not use flammable materials (e.g., hairspray or insec-

ticide) near the product.
Do not clean the product with organic solvents such as 
paint thinner.

The use of organic solvents may crack the product, or cause 
electric shocks or fire.

• Contact professional personnel about attachment of 

accessories and be sure to use only accessories speci-
fied by the manufacturer.

If a defect results from your own workmanship, it may result 
in water leaks, electric shock, or fire.

CAUTION

• Before cleaning, be sure to stop unit operation, turn the 

breaker off or remove the power cord.

Otherwise, an electric shock and injury may result.

• Do not wash the air conditioner with water, as this may 

result in electric shocks or fire. 

• Consult your dealer regarding cleaning the inside of the 

air conditioner.

Improper cleaning may cause breakage of plastic parts, water 
leakage, electric shocks and other damages.

• Watch your step at the time of air filter cleaning or 

inspection.

Working is required in high areas, so extra caution must be 
exercised.
If the scaffold is unstable, you may fall or topple down, thus 
causing injury.

HOW TO CLEAN THE AIR FILTER

(The air filter is a field supply.)
Clean the air filter when the message 

Time to clean filter

 is dis-

played.

• This message is displayed once the unit has operated for a 

certain amount of time.

• Always clean the air filter at the beginning of the heating or 

cooling season. 
Dust and dirt in the air filter reduce airflow, lowering the unit’s 
capacity.

• Clean the air filter more frequently when using the unit in an 

environment with a higher content of pollution.

NOTES

• Do not remove the air filter for other than cleaning purposes. 

Doing so may cause damage to the unit. 
(The unit does not include an air filter as standard equip-
ment.)

• Do not install any object other than a proper air filter in the 

suction inlet (for example, a paper towel). Doing so may 
result in degraded performance and cause freezing or water 
leakage.

1. Reset the filter message when the filter is cleaned or 

replaced.

The 

Time to clean filter

 message turns OFF.

Refer to the operation manual provided with the Remote 
controller for the positions of the 

Time to clean filter

 mes-

sage and how to reset the message.

HOW TO CLEAN AIR OUTLET AND OUTSIDE 
PANELS (Field supply)

1. Clean with soft cloth.

2. When it is difficult to remove stains, use water or neu-

tral detergent.

NOTES

• Do not use gasoline, benzene, thinner, polishing powder, liq-

uid insecticide. It may cause discoloring or warping.

• Do not let the indoor unit get wet. It may cause an electric 

shock or a fire.

• Do not use hot water of 122°F or higher, as doing so may 

result in discoloration or deformation.

3P338600_18B.book  Page 3  Friday, December 13, 2013  7:03 PM

Summary of Contents for FXMQ07PAVJU

Page 1: ...ANUAL English Fran ais Espa ol MODELS Ceiling mounted Duct type FXMQ07PAVJU FXMQ09PAVJU FXMQ12PAVJU FXMQ15PAVJU FXMQ18PAVJU FXMQ24PAVJU FXMQ30PAVJU FXMQ36PAVJU FXMQ48PAVJU FXMQ54PAVJU 00_CV_3P338600_1...

Page 2: ...vous servir correctement de l appar eil et vous guidera en cas de probl me Ce manuel ne d crit que l unit int rieure Utilisez le avec le manuel de l unit ext rieure Lorspue vous aurez lu le manuel ra...

Page 3: ...1 Fig 1 1 2 13 3 4 5 6 7 10 11 12 14 8 9 00_CV_3P338600_18B fm Page 3 Friday December 13 2013 7 04 PM...

Page 4: ...ly use accessories made by Daikin that are specifically designed for use with the equipment and have them installed by a profes sional Contact your dealer to move and reinstall the air condi tioner or...

Page 5: ...due to the heat Do not expose the controller to direct sunlight The LCD display can become discolored and may result in fail to display the data Do not wipe the controller operation panel with benzene...

Page 6: ...of plastic parts water leakage electric shocks and other damages Watch your step at the time of air filter cleaning or inspection Working is required in high areas so extra caution must be exercised...

Page 7: ...u autres pi ces en m tal ou en bois pourraient causer des coupures ou d autres blessures D chirez et jetez les sacs d emballage en plastique pour viter que des enfants ne jouent avec Les enfants jouan...

Page 8: ...Pour tout travail de nettoyage consultez le responsable de l installation Un nettoyage incorrect de l int rieur du climatiseur ris que d entra ner une rupture des pi ces en plastique et de causer une...

Page 9: ...e l unit ext rieure et o le bruit de fonctionnement de l unit ext rieure ne g nent pas les voisins Veillez ce qu il n y ait pas d obstacles proximit de l unit ext rieure Des obstacles se trouvant prox...

Page 10: ...die Consultez votre concessionnaire en ce qui concerne le nettoyage de l int rieur du climatiseur Un nettoyage incorrect peut entra ner la rupture des pi ces en plastique des fuites d eau ou autres d...

Page 11: ...tire las bolsas de pl stico del embalaje de modo que los ni os no puedan jugar con ellas Si los ni os juegan con bolsas de pl stico correr n el peligro de muerte debido a la asfixia ADVERTENCIA Conta...

Page 12: ...ara animales peque os que podr an entrar a la unidad Una vez dentro de la unidad los animales pueden causar mal funcionamiento y provocar humo o fuego cuando hacen contacto con las partes el ctricas N...

Page 13: ...peraci n genera ruidos inusuales Aseg rese que la tuber a de drenaje sea instalada apropiadamente para drenar agua Si no se descarga agua de la tuber a de drenaje mientras el acondiciona dor de aire e...

Page 14: ...da acerca de la limpieza del interior del acondicionador de aire Una limpieza incorrecta puede provocar roturas de las pie zas de pl stico fugas de agua y otros da os as como des cargas el ctricas Vig...

Page 15: ...3P338600_18B book Page 5 Friday December 13 2013 7 03 PM...

Page 16: ...1401 3P338600 18B EM13A014 FS 00_CV_3P338600_18B fm Page 4 Friday December 13 2013 7 04 PM...

Reviews: