4 About the system

Installation and operation manual

10

FXMA-A

VRV system air conditioner

3P680922-1A – 2022.01

4

About the system

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation  may  cause  an  electrical  shock  or  fire.
Contact your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe  and  non-toxic.  R410A  is  a  non-combustible
refrigerant,  and  R32  is  a  mildly  flammable  refrigerant,
but  they  will  generate  a  toxic  gas  when  they
accidentally  leak  into  a  room  where  combustible  air
from  fan  heaters,  gas  cookers,  etc.  is  present.  Always
have  qualified  service  personnel  confirm  that  the  point
of  leakage  has  been  repaired  or  corrected  before
resuming operation.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

NOTICE

For future modifications or expansions of your system:

A  full  overview  of  allowable  combinations  (for  future
system  extensions)  is  available  in  technical  engineering
data  and  should  be  consulted.  Contact  your  installer  to
receive more information and professional advice.

CAUTION

This  unit  is  equipped  with  electrically  powered  safety
measures,  such  as  a  refrigerant  leak  detector.  In  order  to
be  effective,  the  unit  must  be  electrically  powered  at  all
times after installation, except for short service periods.

4.1

System layout

INFORMATION

The  following  illustration  is  an  example  and  might  NOT
match your system layout.

d

e

b

c

a

f

a

Indoor unit

b

Outdoor unit

c

User interface

d

Suction air

e

Discharge air

f

Refrigerant transmission cable

g

Drain pipe

5

User interface

CAUTION

▪ NEVER touch the internal parts of the controller.

▪ Do NOT remove the front panel. Some parts inside are

dangerous  to  touch  and  appliance  problems  may
happen.  For  checking  and  adjusting  the  internal  parts,
contact your dealer.

NOTICE

Do  NOT  wipe  the  controller  operation  panel  with  benzine,
thinner,  chemical  dust  cloth,  etc.  The  panel  may  get
discoloured  or  the  coating  peeled  off.  If  it  is  heavily  dirty,
soak  a  cloth  in  water-diluted  neutral  detergent,  squeeze  it
well  and  wipe  the  panel  clean.  Wipe  it  with  another  dry
cloth.

NOTICE

NEVER press the button of the user interface with a hard,
pointed object. The user interface may be damaged.

NOTICE

NEVER pull or twist the electric wire of the user interface. It
may cause the unit to malfunction.

This operation manual offers a non-exhaustive overview of the main
functions of the system.

For  more  information  about  the  user  interface,  see  the  operation
manual of the installed user interface.

6

Operation

6.1

Operation range

INFORMATION

For  the  operation  limits  see  the  technical  data  of  the
connected outdoor unit.

6.2

About operation modes

INFORMATION

Depending on the installed system, some operation modes
will not be available.

▪ The  air  flow  rate  may  adjust  itself  depending  on  the  room

temperature  or  the  fan  may  stop  immediately.  This  is  not  a
malfunction.

▪ If the main power supply is turned off during operation, operation

will restart automatically after the power turns back on again.

Setpoint.

  Target  temperature  for  the  Cooling,  Heating,  and  Auto

operation modes.

Setback.

 A function that keeps the room temperature in a specific

range  when  the  system  is  turned  off  (by  the  user,  the  schedule
function, or the OFF timer).

6.2.1

Basic operation modes

The indoor unit can operate in various operation modes.

Summary of Contents for FXMA100A5VEB

Page 1: ...Installation and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXMA50A5VEB FXMA63A5VEB FXMA80A5VEB FXMA100A5VEB FXMA125A5VEB...

Page 2: ...bus eksploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpiso...

Page 3: ...roducts are used in accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following the pro...

Page 4: ...e commissioning 21 15 2 To perform a test run 21 16 Configuration 21 16 1 Field setting 21 17 Technical data 23 17 1 Wiring diagram 23 17 1 1 Unified wiring diagram legend 23 1 About the documentation...

Page 5: ...llation of the duct does NOT exceed the setting range of the external static pressure for the unit Refer to the technical datasheet of your model for the setting range Make sure to install the canvas...

Page 6: ...ammable WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that...

Page 7: ...nderstand the hazards involved Children SHALL NOT play with the appliance Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire D...

Page 8: ...ct your dealer WARNING This unit contains electrical and hot parts WARNING Before operating the unit be sure the installation has been carried out correctly by an installer CAUTION It is unhealthy to...

Page 9: ...AMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process...

Page 10: ...erface d Suction air e Discharge air f Refrigerant piping transmission cable g Drain pipe 5 User interface CAUTION NEVER touch the internal parts of the controller Do NOT remove the front panel Some p...

Page 11: ...Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury NOTICE NEVER inspect or service the unit by yourself Ask a qualifi...

Page 12: ...with duct close the protective guard In case of rear suction with duct close service duct opening 9 Turn ON the power 10 To remove warning screens see the reference guide of the user interface 7 2 2 T...

Page 13: ...your dealer immediately For more information see the installation manual of the outdoor unit INFORMATION To stop alarm of the user interface see the reference guide of the user interface INFORMATION...

Page 14: ...ets the requirement for commercial and light industrial location when professionally installed and maintained NOTICE The professional installer shall evaluate the EMC situation before installation if...

Page 15: ...al service space Refer to the installation manual of the used option before installation 12 2 Mounting the indoor unit 12 2 1 Guidelines when installing the indoor unit Installation options CAUTION In...

Page 16: ...the installation of the duct does NOT exceed the setting range of the external static pressure for the unit Refer to the technical datasheet of your model for the setting range Make sure to install t...

Page 17: ...r bubbles Rising piping 300 mm from the unit 625 mm perpendicular to the unit 625 300 0 75 1000 1500 mm b a b a d d c a Metal clamp accessory b Drain hose accessory c Rising drain piping vinyl pipe of...

Page 18: ...1 l of water through the water inlet and check for leaks f e d b a g c a Drain connection b Water inlet c Refrigerant pipes d Drain outlet for maintenance e Water inlet cover f Bucket adding water thr...

Page 19: ...The refrigerant inside this unit is mildly flammable Pipe length Keep refrigerant piping as short as possible Flare connections Connect refrigerant piping to the unit using flare connections Insulati...

Page 20: ...rame and connect the cable to the terminal block L N earth Fix the cable with a tie wrap on the wiring fixture a b a Circuit breaker b Residual current device 10 15 70 90 7 P1P2 F1 F2 b L N 10 15 70 9...

Page 21: ...t they correspond with the actual installation setup and with the needs of the user Bottom suction or rear suction installation External static pressure setting using Airflow automatic adjustment sett...

Page 22: ...up volume 2 02 OFF a 03 Monitoring 1 2 04 Monitoring 2 2 05 a Only use in combination with optional remote sensor or when setting M 10 20 SW 2 03 is used Setting Time to clean air filter This setting...

Page 23: ...tion Contact that can make and break the min load of DC15 V 1 mA This setting must correspond with the needs of the user If you want to set Then 1 M SW Forced OFF 12 22 1 01 ON OFF Operation 02 Emerge...

Page 24: ...e core PAM Pulse amplitude modulation PCB Printed circuit board PM Power module PS Switching power supply PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circuit breaker Q DI KLM Earth...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...3P680922 1A 2022 01 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: