3 User safety instructions

Installation and operation manual

7

FXMA-A
VRV system air conditioner
3P680922-1A – 2022.01

NOTICE

▪ Incomplete flaring may cause refrigerant gas leakage.

▪ Do  NOT  re-use  flares.  Use  new  flares  to  prevent

refrigerant gas leakage.

▪ Use  flare  nuts  that  are  included  with  the  unit.  Using

different flare nuts may cause refrigerant gas leakage.

2.1.1

Installation space requirements

CAUTION

The  total  refrigerant  charge  in  the  system  cannot  exceed
the  requirements  for  minimum  floor  area  of  the  smallest
room that is served. For minimum floor area requirements
for  indoor  units,  see  the  installation  and  operation  manual
of the outdoor unit.

WARNING

This  appliance  contains  R32  refrigerant.  For  the  minimum
floor area of the room in which the appliance is stored refer
to installation and operation manual of the outdoor unit.

NOTICE

▪ Pipework shall be protected from physical damage.

▪ Installation of pipework shall be kept to a minimum.

For the user

3

User safety instructions

Always observe the following safety instructions and regulations.

3.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  the  dismantling  of  the  system,  treatment  of
the  refrigerant,  of  oil  and  of  other  parts  MUST  be  done  by  an
authorised installer and MUST comply with applicable legislation.

Units MUST be treated at a specialised treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste  batteries  MUST  be  treated  at  a  specialised  treatment
facility  for  reuse.  By  ensuring  waste  batteries  are  disposed  of
correctly, you will help to prevent potential negative consequences
for the environment and human health.

Summary of Contents for FXMA100A5VEB

Page 1: ...Installation and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXMA50A5VEB FXMA63A5VEB FXMA80A5VEB FXMA100A5VEB FXMA125A5VEB...

Page 2: ...bus eksploatuojami laikantis m s instrukcij atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpiso...

Page 3: ...roducts are used in accordance with our instructions as amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following the pro...

Page 4: ...e commissioning 21 15 2 To perform a test run 21 16 Configuration 21 16 1 Field setting 21 17 Technical data 23 17 1 Wiring diagram 23 17 1 1 Unified wiring diagram legend 23 1 About the documentation...

Page 5: ...llation of the duct does NOT exceed the setting range of the external static pressure for the unit Refer to the technical datasheet of your model for the setting range Make sure to install the canvas...

Page 6: ...ammable WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that...

Page 7: ...nderstand the hazards involved Children SHALL NOT play with the appliance Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire D...

Page 8: ...ct your dealer WARNING This unit contains electrical and hot parts WARNING Before operating the unit be sure the installation has been carried out correctly by an installer CAUTION It is unhealthy to...

Page 9: ...AMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process...

Page 10: ...erface d Suction air e Discharge air f Refrigerant piping transmission cable g Drain pipe 5 User interface CAUTION NEVER touch the internal parts of the controller Do NOT remove the front panel Some p...

Page 11: ...Do NOT insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury NOTICE NEVER inspect or service the unit by yourself Ask a qualifi...

Page 12: ...with duct close the protective guard In case of rear suction with duct close service duct opening 9 Turn ON the power 10 To remove warning screens see the reference guide of the user interface 7 2 2 T...

Page 13: ...your dealer immediately For more information see the installation manual of the outdoor unit INFORMATION To stop alarm of the user interface see the reference guide of the user interface INFORMATION...

Page 14: ...ets the requirement for commercial and light industrial location when professionally installed and maintained NOTICE The professional installer shall evaluate the EMC situation before installation if...

Page 15: ...al service space Refer to the installation manual of the used option before installation 12 2 Mounting the indoor unit 12 2 1 Guidelines when installing the indoor unit Installation options CAUTION In...

Page 16: ...the installation of the duct does NOT exceed the setting range of the external static pressure for the unit Refer to the technical datasheet of your model for the setting range Make sure to install t...

Page 17: ...r bubbles Rising piping 300 mm from the unit 625 mm perpendicular to the unit 625 300 0 75 1000 1500 mm b a b a d d c a Metal clamp accessory b Drain hose accessory c Rising drain piping vinyl pipe of...

Page 18: ...1 l of water through the water inlet and check for leaks f e d b a g c a Drain connection b Water inlet c Refrigerant pipes d Drain outlet for maintenance e Water inlet cover f Bucket adding water thr...

Page 19: ...The refrigerant inside this unit is mildly flammable Pipe length Keep refrigerant piping as short as possible Flare connections Connect refrigerant piping to the unit using flare connections Insulati...

Page 20: ...rame and connect the cable to the terminal block L N earth Fix the cable with a tie wrap on the wiring fixture a b a Circuit breaker b Residual current device 10 15 70 90 7 P1P2 F1 F2 b L N 10 15 70 9...

Page 21: ...t they correspond with the actual installation setup and with the needs of the user Bottom suction or rear suction installation External static pressure setting using Airflow automatic adjustment sett...

Page 22: ...up volume 2 02 OFF a 03 Monitoring 1 2 04 Monitoring 2 2 05 a Only use in combination with optional remote sensor or when setting M 10 20 SW 2 03 is used Setting Time to clean air filter This setting...

Page 23: ...tion Contact that can make and break the min load of DC15 V 1 mA This setting must correspond with the needs of the user If you want to set Then 1 M SW Forced OFF 12 22 1 01 ON OFF Operation 02 Emerge...

Page 24: ...e core PAM Pulse amplitude modulation PCB Printed circuit board PM Power module PS Switching power supply PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circuit breaker Q DI KLM Earth...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...3P680922 1A 2022 01 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Reviews: