10. Installation
Installation Example
1.
SAFETY CONSIDERATIONS
Read these
SAFETY CONSIDERATIONS
carefully before
installing air conditioning e
q
uipment, and be sure to install it
correctly. After completing the installation, make sure that the
unit operates properly during the start-up operation.
Instruct the customer ho
w
to operate and maintain the unit.
Inform customers that they should store this Installation Man-
ual
w
ith the Operation Manual for future reference.
Al
w
ays use a licensed installer or contractor to install this
product. Improper installation can result in
w
ater or refrigerant
leakage, electrical shock, fire, or explosion.
Meanings of DA
N
GER, WAR
N
I
N
G, CAUTIO
N
, and
N
OTE
symbols are as follo
w
s:
DANGER
.............. Indicates an imminently hazardous
situation
w
hich, if not avoided,
w
ill
result in death or serious injury.
WARNING
............ Indicates a potentially hazardous sit-
uation
w
hich, if not avoided, could
result in death or serious injury.
CAUTION
...............Indicates a potentially hazardous sit-
uation
w
hich, if not avoided, may
result in minor or moderate injury. It
may also be used to alert against
unsafe practices.
NOTE
.................... Indicates situations that may result
in e
q
uipment or propertydamage
accidents only.
DANGER
• Refrigerant gas is heavier than air and displaces oxy-
gen. A massive leak can lead to oxygen depletion,
especially in basements, and an asphyxiation hazard
can occur leading to serious injury or death.
• Do not install unit in an area where flammable mate-
rials are present due to risk of explosions that can
cause serious injury or death.
Refrigerant gas may produce toxic gas if it comes in contact
w
ith fire from a fan, heater, stove, cooking device, or other
heat source. Exposure to this gas can cause severe injury
or death.
• If e
q
uipment utilizing a burner is used in the same
room as the air conditioner, there is the danger of
oxygen deficiency which can lead to an asphyxiation
hazard resulting in serious injury or death.
Be sure to sufficiently ventilate the room to avoid this haz-
ard.
• Any abnormalities in the operation of the air condi-
tioner, such as smoke or fire, can result in severe
injury or death. Turn off the power and contact your
dealer immediately for instructions.
• If e
q
uipment utilizing a burner is used in the same
room as the air conditioner, there is the danger of
oxygen deficiency which can lead to an asphyxiation
hazard resulting in serious injury or death.
Be sure to
sufficiently ventilate the room to avoid this hazard.
• After completing the installation work, check that the
refrigerant gas does not leak.
Refrigerant gas may produce toxic gas if it comes in contact
w
ith fire from a fan, heater, stove, cooking device, or other
heat source. Exposure to this gas can cause severe injury
or death.
Air outlet
Drain pipe
Refrigerant pipe
Grounding
w
ire
Remote controller
Suction grille
Air filter (inside suction grille)
Connection electric
w
ire
Air flo
w
flap (at air outlet)
Discharge air
Inlet air
Wire from the unit into the ground to
prevent electric shock.
3P
N
02401-9X
Summary of Contents for FXHQ-M
Page 1: ...AMERICAS EDUS 39 600 F5 FXHQ M Ceiling Suspended Type...
Page 5: ...Dimensions EDUS39 600 F5 4 FXHQ M 3 Dimensions FXHQ12MVJU 3D049330...
Page 6: ...EDUS39 600 F5 Dimensions FXHQ M 5 FXHQ24MVJU 3D049331...
Page 7: ...Dimensions EDUS39 600 F5 6 FXHQ M FXHQ36MVJU 3D049332...
Page 10: ...EDUS39 600 F5 Electric Characteristics FXHQ M 9 6 Electric Characteristics C 4D049333...