If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

For combination with R410A outdoor unit, refer to the 
following table:

Information requirements for fan coil units

INFORMATION TO IDENTIFY THE MODEL(S) TO WHICH THE 

INFORMATION RELATES:

Item

Symbol Value

Unit Item

Symbol

Value

Unit

Cooling 

capacity 

(sensible)

P

rated, c

A

kW

Total electric 

power input

P

elec

D

kW

Cooling 

capacity 

(latent)

P

rated, c

B

kW

Sound power 

level (per 

speed setting if 

applicable)

L

WA

E

dB

Heating 

capacity

P

rated, h

C

kW

Contact 

details

DAIKIN INDUSTRIES CZECH REPUBLIC s.r.o.

U Nové Hospody 1/1155, 301 00 Plzeň Skvrňany, Czech Republic

THE ABOVE TABLE RELATES TO THE MODELS AND VALUES 

STATED IN THIS TABLE

Models

A

B

C

D

E

FVA125AMVEB

7.83

4.27

13.50

0.24

63

FVA140AMVEB

8.68

4.72

15.50

0.28

65

3. OPERATION RANGE

Outdoor 

units

Cooling

Heating

RZQG

71~140

Outdoor 

temperature

-15~50°C DB

-19~21°C DB

-20~15.5°C WB

Indoor 

temperature

18~37°C DB

12~28°C WB

10~27°C DB

RZQSG

71~140

Outdoor 

temperature

-15~46°C DB

-14~21°C DB

-15~15.5°C WB

Indoor 

temperature

20~37°C DB

14~28°C WB

10~27°C DB

RZQ

200~250

Outdoor 

temperature

-5~46°C DB

-14~21°C DB

-15~15°C WB

Indoor 

temperature

20~37°C DB

14~28°C WB

10~27°C DB

AZQS125

(AVA125 

model only)

Outdoor 

temperature

-5~46°C DB

-15~15.5°C WB

Indoor 

temperature

14~28°C WB

10~27°C DB

Indoor humidity ≤80%

(a)

For combination with R32 outdoor unit, refer to the 
following table:

(a)

 To avoid condensation and water dripping out of the 

unit. If the temperature or the humidity is beyond these 
conditions, safety devices may be put in action and the air 
conditioner may not operate.

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote controller is 
16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-venti-

lated place where there are no obstacles 
around?

• Do not use the air conditioner in the following 

places.

a.Filled with much mineral oil such as cutting oil
b.Where there is much salt such as a beach area
c.Where sulfured gas exists such as a hot-spring 

resort

d.Where there are considerable voltage fluctua-

tions such as a factory or plant

e.Vehicles and vessels

 

f.Where there is much spray of oil and vapor such 

as a cookery, etc.

g.Where there are machines generating electro-

magnetic waves

h.Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer about snow pro-
tection hoods, etc.

Outdoor 

units

Cooling

Heating

RZAG

71~140

Outdoor 

temperature

-20~52°C DB

-19.5~21°C DB

-20~15.5°C WB

Indoor 

temperature

18~37°C DB

12~28°C WB

10~27°C DB

RZASG

71~140

Outdoor 

temperature

-15~46°C DB

-14~21°C DB

-15~15.5°C WB

Indoor 

temperature

20~37°C DB

14~28°C WB

10~27°C DB

AZAS125

(AVA125 

model only)

Outdoor 

temperature

-5~46°C DB

-15~15°C WB

Indoor 

temperature

14~28°C WB

10~27°C DB

Indoor humidity ≤80%

(a)

4. INSTALLATION SITE

3PEN486799-1.book  Page 6  Wednesday, June 14, 2017  9:43 AM

Summary of Contents for FVA71AMVEB

Page 1: ...OPERATION MANUAL FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB Split System Air Conditioner...

Page 2: ...1 English ILLUSTRATION a b c d d e e f f g h i j k l...

Page 3: ...industry and on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 4: ...arth the air conditioner Do not earth the air conditioner to a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge curren...

Page 5: ...r unless you smell something burning or when doing repairs inspection or cleaning of the unit Refrigerant leakage cannot be detected otherwise Only for R32 refrigerant Do not install in sealed highly...

Page 6: ...tdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one ind...

Page 7: ...emperature 14 28 C WB 10 27 C DB Indoor humidity 80 a For combination with R32 outdoor unit refer to the following table a To avoid condensation and water dripping out of the unit If the temperature o...

Page 8: ...gain 5 OPERATION PROCEDURE CHARACTERISTICS OF THE COOLING OPERATION COOLING OPERATION AND AUTOMATIC COOLING OPERATION If the COOLING OPERATION is used when the indoor temperature is low frost forms on...

Page 9: ...emote controller does not display the airflow rate and set temperature The indoor tempera ture detected when the operation button is pressed is the set temperature When the indoor temperature is lower...

Page 10: ...s effective when the flaps are facing slightly upward for cool air and slightly downward for warm air In addition the flaps are separated into No 1 and No 2 groups and this enables up and down airflow...

Page 11: ...OOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do not let the air blow directly to a person Use the TIMER OPERATION effectively It takes some time until the indoor tempe...

Page 12: ...of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 Turn off the indication or Time to clean filter displayed on the remote con troll...

Page 13: ...rating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air filter and exterior Be sure to r...

Page 14: ...Even if the fan speed control button is pressed the fan speed does not change During the COOLING OPERATION the airflow rate is lowered to prevent the carryover of melted water In addition during DEFR...

Page 15: ...ishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise VIII DUST FROM THE...

Page 16: ...ent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling If the heat source of the room is excessive...

Page 17: ...ied with the controller are marked with this symbol This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste For batteries a chemical sy...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2017 Daikin 3P486799 1 2017 05...

Reviews: