VI. WHITE MIST COMES OUT OF A UNIT

• When humidity is high during COOLING 

OPERATION (In oily or dusty places)

If the inside of an indoor unit is extremely con-
taminated, the temperature distribution inside a 
room becomes uneven. It is necessary to clean 
the inside of the indoor unit. Ask your Daikin 
dealer for details on cleaning the unit. This oper-
ation requires a qualified service person.
Check the usage environment.

• When the operation is switched to the HEAT-

ING OPERATION during or after the DEFROST 
OPERATION.

Moisture generated by DEFROST becomes 
steam and will float around.
When the remote controller display shows 

”, the unit is in DEFROST OPERATION.

VII.NOISE OF AIR CONDITIONERS

• A ringing sound after the unit starts.

This sound is generated when the motors for 
driving the airflow flaps are working.
It will quiet down after about a minute.

• A continuous flow “Shuh” sound is heard 

when the systems is in COOLING or 
DEFROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• A “Shuh” sound which is heard at the start or 

immediately after the stop of operation or 
which is heard at the start or immediately 
after the stop of DEFROST OPERATION. 

This is the noise of refrigerant caused by flow 
stop and flow change.
During HEATING OPERATION, the system 
switches to DEFROST OPERATION automati-
cally. The remote controller shows “

”.

After 6 to 8 minutes (maximum 10 minutes), the 
system returns to its original operation.

• A continuous flow “Shah”  sound is heard 

when the system is in COOLING OPERATION 
or at a stop.

The noise is heard when the drain pump is in 
operation.
Moisture removed from the indoor air during the 
COOLING OPERATION is drained. (The drain-
ing device is provided as an optional part.)

• A “Pishi-pishi” squeaking sound is heard 

when the system is in operation or after the 
stop of operation.

Expansion and contraction of plastic parts 
caused by temperature change makes this 
noise.

VIII.DUST FROM THE UNITS

• Dust may blow out from the unit after starting 

operation from long resting time.

Dust absorbed by the unit blows out.

IX. THE UNITS GIVE OFF ODORS

• During operation

The unit absorbs the smell of rooms, furniture, 
cigarettes, etc., and then emits them.
If odor is a concern, you can set to zero airflow 
rate when the indoor temperature reaches the 
set temperature.
For details, contact your Daikin dealer.

X. THE UNIT DOES NOT COOL EFFECTIVELY.

• The unit is operating in program dry mode.

This is because program dry mode operates so 
that the indoor temperature decreases as little 
as possible.
Lower the indoor temperature using COOLING 
OPERATION, and then use PROGRAM DRY 
OPERATION.
(Refer to “CHARACTERISTICS OF THE PRO-
GRAM DRY OPERATION” on page 8.)

Read through characteristics of the COOLING 
OPERATION, characteristics of the HEATING 
OPERATION, and characteristics of the PRO-
GRAM DRY OPERATION on page 7, 8.

This unit is equipped with a refrigerant leak detector 
for safety. To be effective, the unit must be 
electrically powered at all times after installation, 
other than short service intervals (only for R32 
refrigerant).

Please check before requesting a service call.

1. If the system does not operate at all.

Check if fuse has blown.
Turn off the power supply.

Check if the power circuit breaker is blown.
Turn the power on with the power circuit 
breaker switch in the off position.
Do not turn the power on with the power circuit 
breaker switch in the trip position.
(Contact your dealer.)

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

10. TROUBLE SHOOTING

Tab

Trip position

Power circuit breaker
(earth leakage breaker)

ON

OFF

3PEN486799-1.book  Page 14  Wednesday, June 14, 2017  9:43 AM

Summary of Contents for FVA71AMVEB

Page 1: ...OPERATION MANUAL FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB Split System Air Conditioner...

Page 2: ...1 English ILLUSTRATION a b c d d e e f f g h i j k l...

Page 3: ...industry and on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 4: ...arth the air conditioner Do not earth the air conditioner to a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge curren...

Page 5: ...r unless you smell something burning or when doing repairs inspection or cleaning of the unit Refrigerant leakage cannot be detected otherwise Only for R32 refrigerant Do not install in sealed highly...

Page 6: ...tdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one ind...

Page 7: ...emperature 14 28 C WB 10 27 C DB Indoor humidity 80 a For combination with R32 outdoor unit refer to the following table a To avoid condensation and water dripping out of the unit If the temperature o...

Page 8: ...gain 5 OPERATION PROCEDURE CHARACTERISTICS OF THE COOLING OPERATION COOLING OPERATION AND AUTOMATIC COOLING OPERATION If the COOLING OPERATION is used when the indoor temperature is low frost forms on...

Page 9: ...emote controller does not display the airflow rate and set temperature The indoor tempera ture detected when the operation button is pressed is the set temperature When the indoor temperature is lower...

Page 10: ...s effective when the flaps are facing slightly upward for cool air and slightly downward for warm air In addition the flaps are separated into No 1 and No 2 groups and this enables up and down airflow...

Page 11: ...OOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do not let the air blow directly to a person Use the TIMER OPERATION effectively It takes some time until the indoor tempe...

Page 12: ...of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 Turn off the indication or Time to clean filter displayed on the remote con troll...

Page 13: ...rating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air filter and exterior Be sure to r...

Page 14: ...Even if the fan speed control button is pressed the fan speed does not change During the COOLING OPERATION the airflow rate is lowered to prevent the carryover of melted water In addition during DEFR...

Page 15: ...ishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise VIII DUST FROM THE...

Page 16: ...ent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling If the heat source of the room is excessive...

Page 17: ...ied with the controller are marked with this symbol This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste For batteries a chemical sy...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2017 Daikin 3P486799 1 2017 05...

Reviews: