background image

English

2

CONTENTS

ILLUSTRATION ............................................. 1

1. SAFETY PRACECAUTIONS ......................... 2
2. WHAT TO DO BEFORE OPERATION .......... 5
3. OPERATION RANGE .................................... 6
4. INSTALLATION SITE .................................... 6
5. OPERATION PROCEDURE .......................... 7
6. OPERATION CHARACTERISTICS ............... 7
7. OPTIMUM OPERATION .............................. 10
8. MAINTENANCE 

(FOR SERVICE PERSONNEL) ................... 10

9. NOT A MALFUNCTION OF THE AIR 

CONDITIONER............................................ 12

10. TROUBLE SHOOTING ................................ 14
11. DISPOSAL REQUIREMENTS ..................... 16

Thank you for purchasing this Daikin air conditioner. 
Carefully read this operation manual before using 
the air conditioner. It will tell you how to use the unit 
properly and help you if any trouble occurs. After 
reading the manual, file it away for future reference. 
Furthermore, make certain that this operation man-
ual is handed to a new user when he takes over the 
operation.
The original instructions are written in English. 
All other languages are translations of the original 
instructions.
This operation manual is dedicated for the indoor 
unit. Also refer to the operation manuals provided 
with the outdoor unit and remote controller.

2087.5

Refrigerant type:

Refrigerant type:

GWP

(1)

 value:

GWP

(1)

 value:

675

R410A

R32

(1)

 GWP = global warming potential 

This product contains fluorinated greenhouse gases. 
Do not vent gases into the atmosphere.

NOTICE 

regarding tCO

2

eq

Periodical inspections for refrigerant leaks may be 
required depending on European or local legislation. 
Please contact your local dealer for more information.

In Europe, the 

greenhouse gas emissions 

of the 

total  refrigerant charge in the system (expressed as 
tonnes CO

-equivalent) is used to determine the 

maintenance intervals. Follow the applicable 
legislation.

Formula to calculate the greenhouse gas 
emissions:

GWP value of the refrigerant × Total refrigerant 
charge [in kg] / 1000

Important information regarding the 
refrigerant used

To gain full advantage of the air conditioner’s functions and to 
avoid malfunction due to mishandling, please read this opera-
tion manual carefully before use.

This appliance is intended to be used by expert or 
trained users in shops, in light industry and on farms, 
or for commercial use by lay persons.
This appliance can be used by children aged from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and user 
maintenance shall only be done by persons described 
in manual.
The appliance is not intended for use by unattended 
young children or persons who are incompetent to 
operate air conditioners.

It may result in injury or electric shocks.

This manual classifies the precautions into WARNINGS 
and CAUTIONS. Be sure to follow all the precautions 
below: They are all important for ensuring safety.

WARNING

....... Indicates a potentially hazardous situation 

which, if not avoided, could result in death 
or serious injury.

CAUTION

........ Indicates a potentially hazardous situation 

which, if not avoided, may result in minor 
or moderate injury. 
It may also be used to alert against unsafe 
practices.

After reading, keep this manual in a convenient place so 
that you can refer to it whenever necessary. If the equip-
ment is transferred to a new user, be sure also to hand 
over the manual.

WARNING

When the air conditioner is malfunctioning (giving off a 
burning odor, etc.), turn off the power to the air condi-
tioner and contact your local dealer.

Continued operation under such circumstances may result 
in a failure, electric shocks or a fire.

Consult your local dealer regarding modification, 
repair and maintenance of the air conditioner.

Improper workmanship may result in water leakage, electric 
shocks or a fire.

Be sure to use fuses with the correct ampere reading.

Do not use improper fuses, copper or other wiring as a sub-
stitute, as this may result in electric shocks, a fire, injury or 
damage to the air conditioner.

Consult your local dealer if the air conditioner sub-
merges owing to a natural disaster, such as a flood or 
typhoon.

Do not operate the air conditioner in that case, or otherwise 
a malfunction, electric shocks, or a fire may result.

1. SAFETY PRACECAUTIONS

7KLVDSSOLDQFHLV¿OOHGZLWK5

3PEN486799-1.book  Page 2  Wednesday, June 14, 2017  9:43 AM

Summary of Contents for FVA71AMVEB

Page 1: ...OPERATION MANUAL FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB Split System Air Conditioner...

Page 2: ...1 English ILLUSTRATION a b c d d e e f f g h i j k l...

Page 3: ...industry and on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 4: ...arth the air conditioner Do not earth the air conditioner to a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge curren...

Page 5: ...r unless you smell something burning or when doing repairs inspection or cleaning of the unit Refrigerant leakage cannot be detected otherwise Only for R32 refrigerant Do not install in sealed highly...

Page 6: ...tdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one ind...

Page 7: ...emperature 14 28 C WB 10 27 C DB Indoor humidity 80 a For combination with R32 outdoor unit refer to the following table a To avoid condensation and water dripping out of the unit If the temperature o...

Page 8: ...gain 5 OPERATION PROCEDURE CHARACTERISTICS OF THE COOLING OPERATION COOLING OPERATION AND AUTOMATIC COOLING OPERATION If the COOLING OPERATION is used when the indoor temperature is low frost forms on...

Page 9: ...emote controller does not display the airflow rate and set temperature The indoor tempera ture detected when the operation button is pressed is the set temperature When the indoor temperature is lower...

Page 10: ...s effective when the flaps are facing slightly upward for cool air and slightly downward for warm air In addition the flaps are separated into No 1 and No 2 groups and this enables up and down airflow...

Page 11: ...OOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do not let the air blow directly to a person Use the TIMER OPERATION effectively It takes some time until the indoor tempe...

Page 12: ...of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 Turn off the indication or Time to clean filter displayed on the remote con troll...

Page 13: ...rating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air filter and exterior Be sure to r...

Page 14: ...Even if the fan speed control button is pressed the fan speed does not change During the COOLING OPERATION the airflow rate is lowered to prevent the carryover of melted water In addition during DEFR...

Page 15: ...ishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise VIII DUST FROM THE...

Page 16: ...ent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling If the heat source of the room is excessive...

Page 17: ...ied with the controller are marked with this symbol This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste For batteries a chemical sy...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2017 Daikin 3P486799 1 2017 05...