background image

3

English

Start or stop the air conditioner with the remote con-
troller. Never use the power circuit breaker for this pur-
pose. 

Otherwise, it may cause a fire or water leakage. Further-
more, if an automatic restart control is provided against 
power failure and the power is recovered, the fan will rotate 
suddenly and may cause injury.

Do not use the air conditioner in the atmosphere con-
taminated with oil vapor, such as cooking oil or 
machine oil vapor.

Oil vapor may cause crack damage to the air conditioner, 
electric shocks, or a fire.

Do not use flammable materials (e.g., hairspray or 
insecticide) near the air conditioner.
Do not clean the air conditioner with organic solvents 
such as paint thinner.

The use of organic solvents may cause crack damage to 
the air conditioner, electric shocks, or a fire.

Do not use the air conditioner in places with excessive 
oily smoke, such as cooking rooms, or in places with 
flammable gas, corrosive gas, or metal dust.

Using the air conditioner in such places may cause a fire or 
air conditioner failures.

Beware of a fire in case of refrigerant leakage.

If the air conditioner is not operating correctly, i.e. not gen-
erating cool or warm air, refrigerant leakage could be the 
cause. Consult your local dealer for assistance. The refrig-
erant used for the air conditioner is safe and normally does 
not leak. However, if the refrigerant leaks and gets in con-
tact with a naked burner, heater or cooker, it may generate 
hazardous compounds. Turn off the air conditioner and call 
your local dealer. Turn on the air conditioner after the qual-
ified service person makes sure to confirm that the leakage 
is repaired.

Do not place objects, including rods, your fingers, etc., 
in the air inlet or outlet.

Injury may result due to contact with the air conditioner’s 
highspeed fan blades.

Consult your local dealer regarding cleaning the inside 
of the air conditioner.

Improper cleaning may cause breakage of plastic parts, 
water leakage and other damage as well as electric shocks.

Be aware that prolonged, direct exposure to cool or 
warm air from the air conditioner, or to air that is too 
cool or too warm can be harmful to your physical con-
dition and health.
Consult your local dealer about installation work.

Doing the work yourself may result in water leakage, elec-
tric shocks or a fire.

Contact professional personnel about attachment of 
accessories and be sure to use only accessories spec-
ified by the manufacturer.

If a defect results from your own workmanship, it may result 
in water leakage, electric shocks or a fire.

Consult your local dealer regarding relocation and 
reinstallation of the air conditioner.

Improper installation work may result in leakage, electric 
shocks or a fire.

Be sure to earth the air conditioner.

Do not earth the air conditioner to a utility piping, lightning 
conductor or telephone earth lead.
Imperfect earthing may result in electric shocks or a fire.
A high surge current from lightning or other sources may 
cause damage to the air conditioner.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 
electric shocks or a fire.

Be sure to use a dedicated power supply for the air 
conditioner.

The use of any other power supply may cause heat gener-
ation, a fire, or air conditioner failures.

Consult your local dealer regarding what to do in case 
of refrigerant leakage.

When the air conditioner is installed in a small room, it is 
necessary to take proper measures so that the amount of 
any leaked refrigerant does not exceed the concentration 
limit in the event of a leakage. Otherwise, this may lead to 
an accident due to oxygen depletion.

CAUTION

Children should be watched so that they do not play 
with the indoor unit or its remote controller.

Accidental operation by a child may result in injury or elec-
tric shocks.

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

Falling or tumbling may result in injury.

Do not let children play on or around the outdoor unit.

If they touch the unit carelessly, injury may be caused.

Be sure that children, plants or animals are not 
exposed directly to airflow from the indoor unit, as 
adverse effects may ensue.
Do not place flammable sprays or operate spray con-
tainers near the air conditioner as this may result in a 
fire.
Do not wash the air conditioner or the remote control-
ler with water, as this may result in electric shocks or 
fire.
Do not place water containers (flower vases, etc.) on 
the indoor unit, as this may result in electric shocks or 
a fire.
Do not put flammable containers, such as spray cans, 
within 1 m from the air outlet.

The containers may explode because the warm air from the 
indoor or outdoor unit will affect them.

Turn off the power when the air conditioner is not used 
for long periods of time (only for R410A refrigerant).

Otherwise, the air conditioner may get hot or catch on a fire 
due to dust accumulation.

Do not place objects in direct proximity of the outdoor 
unit and do not let leaves and other debris accumulate 
around the unit.

Leaves are a hotbed for small animals which can enter the 
unit. Once in the unit, such animals can cause malfunc-
tions, smoke or a fire when making contact with electrical 
parts.

To avoid electric shocks, do not operate with wet 
hands.
Never touch the internal parts of the remote controller.

Touching certain internal parts will cause electric shocks 
and damage to the remote controller. Consult your local 
dealer about checking and adjustment of internal parts.

To avoid oxygen deficiency, ensure that the room is 
adequately ventilated if equipment such as a burner is 
used together with the air conditioner.

3PEN486799-1.book  Page 3  Wednesday, June 14, 2017  9:43 AM

Summary of Contents for FVA71AMVEB

Page 1: ...OPERATION MANUAL FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB Split System Air Conditioner...

Page 2: ...1 English ILLUSTRATION a b c d d e e f f g h i j k l...

Page 3: ...industry and on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 4: ...arth the air conditioner Do not earth the air conditioner to a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge curren...

Page 5: ...r unless you smell something burning or when doing repairs inspection or cleaning of the unit Refrigerant leakage cannot be detected otherwise Only for R32 refrigerant Do not install in sealed highly...

Page 6: ...tdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one ind...

Page 7: ...emperature 14 28 C WB 10 27 C DB Indoor humidity 80 a For combination with R32 outdoor unit refer to the following table a To avoid condensation and water dripping out of the unit If the temperature o...

Page 8: ...gain 5 OPERATION PROCEDURE CHARACTERISTICS OF THE COOLING OPERATION COOLING OPERATION AND AUTOMATIC COOLING OPERATION If the COOLING OPERATION is used when the indoor temperature is low frost forms on...

Page 9: ...emote controller does not display the airflow rate and set temperature The indoor tempera ture detected when the operation button is pressed is the set temperature When the indoor temperature is lower...

Page 10: ...s effective when the flaps are facing slightly upward for cool air and slightly downward for warm air In addition the flaps are separated into No 1 and No 2 groups and this enables up and down airflow...

Page 11: ...OOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do not let the air blow directly to a person Use the TIMER OPERATION effectively It takes some time until the indoor tempe...

Page 12: ...of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 Turn off the indication or Time to clean filter displayed on the remote con troll...

Page 13: ...rating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air filter and exterior Be sure to r...

Page 14: ...Even if the fan speed control button is pressed the fan speed does not change During the COOLING OPERATION the airflow rate is lowered to prevent the carryover of melted water In addition during DEFR...

Page 15: ...ishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise VIII DUST FROM THE...

Page 16: ...ent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling If the heat source of the room is excessive...

Page 17: ...ied with the controller are marked with this symbol This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste For batteries a chemical sy...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2017 Daikin 3P486799 1 2017 05...

Reviews: