background image

English

4

Do not leave the remote controller wherever there is a 
risk of wetting.

If water gets into the remote controller there is a risk of elec-
trical leakage and damage to electronic components.

Do not remove the outdoor unit’s outlet side grille.

The grille protects against the unit’s high speed fan, which 
may cause injury.

After prolonged use, check the unit stand and its 
mounts for damage.

If left in a damaged condition, the unit may fall and cause 
injury.

To avoid injury, do not touch the air inlet or aluminum 
fins of the air conditioner.
Do not place objects that are susceptible to moisture 
directly beneath the indoor or outdoor units.

Under certain conditions, condensation on the unit or refrig-
erant piping, air filter dirt or drain blockage may cause drip-
ping, resulting in fouling or failure of the object concerned.

Do not place appliances that produce naked flames in 
places exposed to the airflow from the air conditioner 
as this may impair combustion of the burner.
Do not block air inlets nor outlets.

Impaired airflow may result in insufficient performance or 
trouble.

Do not use the air conditioner for purposes other than 
those for which it is intended.

Do not use the air conditioner for cooling precision instru-
ments, food, plants, animals or works of art as this may 
adversely affect the performance, quality and/or longevity 
of the object concerned.

Do not install the air conditioner at any place where 
there is a danger of flammable gas leakage.

In the event of a gas leakage, build-up of gas near the air 
conditioner may result in a fire.

Carry out drain piping properly to ensure complete 
drainage.

If drain piping is not carried out properly, drain will not flow 
out. Then, dirt and debris may be accumulated in the drain 
piping and may cause water leakage. If it occurs, stop the 
air conditioner and call your local dealer for assistance.

Do not turn off the breaker unless you smell something 
burning, or when doing repairs, inspection or cleaning 
of the unit.

Refrigerant leakage cannot be detected otherwise. (Only 
for R32 refrigerant)

Do not install in sealed, highly airtight spaces such as 
soundproof chambers and room which was sealed up 
the door (only for R32 refrigerant).
Do not use flammable substances (such as hairsprays 
or insecticides etc.) near the unit.

It could cause electric shock, fire, or a misdetection of the 
refrigerant sensor (only for R32 refrigerant).

Do not install in places filled with smoke, gas, chemi-
cals etc.

There is a possibility that the sensors inside the indoor unit 
could detect these, and display a refrigerant leak abnormal-
ity (only for R32 refrigerant).

This unit is equipped with electrically powered safety 
measures. To be effective, the unit must be electrically 
powered at all times after installation, other than short 
service intervals (only for R32 refrigerant).
Before cleaning, be sure to stop the operation, turn the 
breaker off or pull out the power supply cord.
After cleaning, quickly turn the power supply breaker 
back on.

• NOTE TO SERVICE PERSONNEL

CAUTION

Read the following for the safety.

Do not operate the unit while the suction grille is 
open.

Fan may rotate and cause accident.

Make sure to screw the suction grille stopper.

If the screw is not completely tightened, the suc-
tion grille may come off and you may cut your fin-
gers with the fan.

After the installation or service maintenance, 
make sure to put the grille stopper to where it was 
with screws.
(R & L, total 2:see the below.)

WARNING

May cause electric shock, ignition, fire

Before starting the inspection of the electrical 
parts (control box, fan motor, drain pump, etc.), be 
sure cut off the all air-conditioner power (adaptor 
for wiring power is included) or you may get an 
electric shock.

When cleaning the heat exchanger, be sure to 
remove the switch box, fan motor and drain 
pump.
Water or detergent may deteriorate the insulation 
of electric components and result in burn-out of 
these components.

Grille stopper

Grille fixture

Suction grille

Front panel

Tapping screw

3PEN486799-1.book  Page 4  Wednesday, June 14, 2017  9:43 AM

Summary of Contents for FVA71AMVEB

Page 1: ...OPERATION MANUAL FVA71AMVEB FVA100AMVEB FVA125AMVEB FVA140AMVEB Split System Air Conditioner...

Page 2: ...1 English ILLUSTRATION a b c d d e e f f g h i j k l...

Page 3: ...industry and on farms or for commercial use by lay persons This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack o...

Page 4: ...arth the air conditioner Do not earth the air conditioner to a utility piping lightning conductor or telephone earth lead Imperfect earthing may result in electric shocks or a fire A high surge curren...

Page 5: ...r unless you smell something burning or when doing repairs inspection or cleaning of the unit Refrigerant leakage cannot be detected otherwise Only for R32 refrigerant Do not install in sealed highly...

Page 6: ...tdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one ind...

Page 7: ...emperature 14 28 C WB 10 27 C DB Indoor humidity 80 a For combination with R32 outdoor unit refer to the following table a To avoid condensation and water dripping out of the unit If the temperature o...

Page 8: ...gain 5 OPERATION PROCEDURE CHARACTERISTICS OF THE COOLING OPERATION COOLING OPERATION AND AUTOMATIC COOLING OPERATION If the COOLING OPERATION is used when the indoor temperature is low frost forms on...

Page 9: ...emote controller does not display the airflow rate and set temperature The indoor tempera ture detected when the operation button is pressed is the set temperature When the indoor temperature is lower...

Page 10: ...s effective when the flaps are facing slightly upward for cool air and slightly downward for warm air In addition the flaps are separated into No 1 and No 2 groups and this enables up and down airflow...

Page 11: ...OOLING or PROGRAM DRY OPERATION and set it downwards during HEATING OPERATION Do not let the air blow directly to a person Use the TIMER OPERATION effectively It takes some time until the indoor tempe...

Page 12: ...of that in step 2 7 Lock the suction grille Flip down the lock lever using the reverse proce dure of that in step 1 8 Turn off the indication or Time to clean filter displayed on the remote con troll...

Page 13: ...rating Turn off the power circuit breaker for saving energy The display on the remote controller will vanish when the power circuit breaker is turned off Clean the air filter and exterior Be sure to r...

Page 14: ...Even if the fan speed control button is pressed the fan speed does not change During the COOLING OPERATION the airflow rate is lowered to prevent the carryover of melted water In addition during DEFR...

Page 15: ...ishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise VIII DUST FROM THE...

Page 16: ...ent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling If the heat source of the room is excessive...

Page 17: ...ied with the controller are marked with this symbol This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste For batteries a chemical sy...

Page 18: ......

Page 19: ......

Page 20: ...Copyright 2017 Daikin 3P486799 1 2017 05...