SiUS04-904
Piping Diagrams
260
Appendix
RXS15/18DVJU, RX15/18FVJU
RXS24FVJU, RX24FVJU
OUTDOOR UNIT
1/2CuT
1/2CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
DISCHARGE PIPE
THERMISTOR
HEAT
EXCHANGER
THERMISTOR
PROPELLER FAN
MUFFLER
M
HEAT EXCHANGER
5/16CuT
5/16CuT
FOUR-WAY
VALVE
ON:HEATING
COMPRESSOR
1/2CuT
1/2CuT
12.7CuT/
5/16CuT
5/16CuT
5/16CuT
5/16CuT
OUTDOOR AIR TEMPERATURE
THERMISTOR
ACCUMULATOR
CAPILLARY TUBE 4
CAPILLARY TUBE 2
CAPILLARY TUBE 3
CAPILLARY TUBE 1
1/4CuT
MUFFLER
WITH
FILTER
MUFFLER
WITH FIL
TER
1/2CuT
FIL
TER
1/4CuT
1/4CuT
1/4CuT
GAS STOP VALVE
WITH SERVICE PORT
MOTOR OPERATED
VALVE
LIQUID
STOP VALVE
FIELD PIPING
(1/2 CuT)
FIELD PIPING
(1/4 CuT)
REFRIGERANT FLOW
COOLING
HEATING
3D047141B
OUTDOOR UNIT
1/2CuT
1/2CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
5/16CuT
DISCHARGE PIPE
THERMISTOR
HEAT
EXCHANGER
THERMISTOR
PROPELLER FAN
MUFFLER
M
HEAT EXCHANGER
5/16CuT
5/16CuT
FOUR-WAY
VALVE
ON:HEATING
COMPRESSOR
1/2CuT
1/2CuT
12.7CuT/
5/16CuT
5/16CuT
5/16CuT
5/16CuT
OUTDOOR AIR TEMPERATURE
THERMISTOR
ACCUMULATOR
CAPILLARY TUBE 4
CAPILLARY TUBE 2
CAPILLARY TUBE 3
CAPILLARY TUBE 1
1/4CuT
MUFFLER
WITH
FILTER
MUFFLER
WITH FIL
TER
1/2CuT
FIL
TER
1/4CuT
1/4CuT
1/4CuT
GAS STOP VALVE
WITH SERVICE PORT
MOTOR OPERATED
VALVE
LIQUID
STOP VALVE
FIELD PIPING
(5/8 CuT)
FIELD PIPING
(1/4 CuT)
REFRIGERANT FLOW
HEATING
COOLING
3D050325A
Summary of Contents for FTXS09HVJU
Page 1: ...SiUS04 904 Applied Models Inverter Pair Heat Pump Inverter Pair Wall Mounted Type H Series...
Page 9: ...Safety Considerations SiUS04 904 viii Safety Considerations...
Page 10: ...SiUS04 904 List of Functions 1 Part 1 List of Functions 1 Functions 2...
Page 72: ...Control Specification 15 18 24 Class SiUS04 904 62 Function and Control...
Page 77: ...FTXS09 12HVJU SiUS04 904 66 Operation Manual...
Page 78: ...SiUS04 904 FTXS09 12HVJU Operation Manual 67...
Page 83: ...FTXS09 12HVJU SiUS04 904 72 Operation Manual is no longer displayed on the LCD...
Page 84: ...SiUS04 904 FTXS09 12HVJU Operation Manual 73 is no longer displayed on the LCD...
Page 85: ...FTXS09 12HVJU SiUS04 904 74 Operation Manual...
Page 86: ...SiUS04 904 FTXS09 12HVJU Operation Manual 75...
Page 87: ...FTXS09 12HVJU SiUS04 904 76 Operation Manual 3P232717 1C...
Page 90: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 79 is no longer displayed on the LCD...
Page 91: ...FTXS15 18 24HVJU SiUS04 904 80 Operation Manual...
Page 94: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 83 is no longer displayed on the LCD...
Page 95: ...FTXS15 18 24HVJU SiUS04 904 84 Operation Manual Do not hit or forcefully push the operation...
Page 96: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 85 is no longer displayed on the LCD...
Page 97: ...FTXS15 18 24HVJU SiUS04 904 86 Operation Manual is no longer displayed on the LCD...
Page 98: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 87 is no longer displayed on the LCD...
Page 99: ...FTXS15 18 24HVJU SiUS04 904 88 Operation Manual...
Page 100: ...SiUS04 904 FTXS15 18 24HVJU Operation Manual 89...
Page 101: ...FTXS15 18 24HVJU SiUS04 904 90 Operation Manual 3P232717 2C...