background image

3 About the system

Operation manual

5

FTXM20~4 FTXM20~71R2V1B
Daikin room air conditioner
3P485919-11S – 2020.06

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

CAUTION

The  indoor  unit  contains  radio  equipment,  minimum
separation  distance  between  the  radiating  part  of  the
equipment and the user is 10 cm.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation may cause an electric shock or fire. Contact
your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

3.1.1

Indoor unit display

ON/

OFF

a
b

c

d

e

a

Signal receiver for user interface

b

Operation lamp

c

Timer lamp

d

Intelligent eye lamp

e

ON/OFF button

ON/OFF button

If the user interface is missing, you can use the ON/OFF button on
the  indoor  unit  to  start/stop  operation.  When  operation  is  started
using this button, the following settings are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.2

About the user interface

Direct  sunlight.

  Do  NOT  expose  the  user  interface  to  direct

sunlight.

Dust.

  Dust  on  the  signal  transmitter  or  receiver  will  reduce

sensitivity. Wipe off dust with a soft cloth.

Fluorescent  lights.

  Signal  communication  might  be  disabled  if

fluorescent  lamps  are  in  the  room.  In  that  case,  contact  your
installer.

Other  appliances.

  If  the  user  interface  signals  operate  other

appliances, move the other appliances, or contact your installer.

Curtains.

 Make sure that the signal between the unit and the user

interface is NOT blocked by curtains or other objects.

NOTICE

▪ Do NOT drop the user interface.

▪ Do NOT let the user interface get wet.

3.2.1

Components: User interface

d

a

g

m

h

c

b

n

l

f

e

i

j

k

p
o

a

Signal transmitter

b

LCD display

c

Temperature adjustment button

d

ON/OFF button

e

Vertical swing button

f

Horizontal swing button

g

Comfort airflow and Intelligent eye operation button

h

Select button

i

Clock and indoor unit display brightness button

j

OFF/ON timer operation buttons

k

Weekly timer operation buttons

l

Flash Streamer (air cleaning) operation button

m

Econo and Outdoor unit quiet operation button

n

Mode button

o

Powerful button

p

Fan button

4

Before operation

4.1

To insert the batteries

The batteries will last for about 1 year.

Summary of Contents for FTXM71R Series

Page 1: ...EN Daikin Perfera FTXM71R RXM71R...

Page 2: ...m air conditioner English Operation manual Daikin room air conditioner CTXM15R2V1B CTXM15R5V1B FTXM20R2V1B FTXM20R5V1B FTXM25R2V1B FTXM25R5V1B FTXM35R2V1B FTXM35R5V1B FTXM42R2V1B FTXM42R5V1B FTXM50R2V...

Page 3: ...eless LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving an...

Page 4: ...orted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are...

Page 5: ...gerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odour...

Page 6: ......

Page 7: ...ndoor unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 8: ...high low off 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the...

Page 9: ...ion mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be set as fo...

Page 10: ...l automatic swing is selected Comfort airflow operation will be cancelled 5 5 2 Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and te...

Page 11: ...e Econo operation can be only set when the unit is running Pressing cancels the setting and disappears from the LCD Note remains on the LCD even if you turn off the unit using the user interface or in...

Page 12: ......

Page 13: ...displayed on the LCD 5 10 Weekly timer operation With this operation you can save up to 4 timer settings for each day of the week Example Create a different setting from Monday to Friday and a differ...

Page 14: ...cted day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will be copied 4 Press or to select the...

Page 15: ...3 Follow the directions on the screen to install 5 11 3 To set the wireless connection There are two options to connect the wireless adapter with your smart device Connect the wireless LAN to your sma...

Page 16: ...y default in case you want to disconnect the wireless LAN and the communication device e g router or smart device repeat the setting if the connection was unsuccessful 1 On home screen menu hold for a...

Page 17: ...orinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 NOTICE Applicable legislation on fluorinated greenhouse gases requires that...

Page 18: ......

Page 19: ...it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult to remove stains use water or a neutral dete...

Page 20: ...lter and the silver allergen removal air purifying filter contact your dealer Item Part number Titanium deodorising filter 1 set KAF970A46 Silver allergen removal air purifying filter 1 set KAF057A41...

Page 21: ...tems it is impossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date poss...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 11S 2020 06 Copyright 2...

Page 26: ......

Reviews: