2 User safety instructions

Operation manual

4

FTXM20~4 FTXM20~71R2V1B

Daikin room air conditioner

3P485919-11S – 2020.06

WARNING

Do NOT place objects below the indoor
and/or outdoor unit that may get wet.
Otherwise condensation on the unit or
refrigerant pipes, air filter dirt or drain
blockage may cause dripping, and
objects under the unit may get dirty or
damaged.

WARNING

Do NOT place a flammable spray
bottle near the air conditioner and do
NOT use sprays near the unit. Doing
so may result in a fire.

CAUTION

Do NOT operate the system when
using a room fumigation-type
insecticide. Chemicals could collect in
the unit, and endanger the health of
people who are hypersensitive to
chemicals.

WARNING

The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.

Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.

Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The appliance shall be stored in a
room without continuously operating
ignition sources (example: open
flames, an operating gas appliance or
an operating electric heater).

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies off. Otherwise, an
electric shock and injury may result.

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

CAUTION

Do NOT touch the heat exchanger fins.
These fins are sharp and could result
in cutting injuries.

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker off or pull
out the supply cord. Otherwise, an
electric shock and injury may result.

WARNING

Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.

Summary of Contents for FTXM71R Series

Page 1: ...EN Daikin Perfera FTXM71R RXM71R...

Page 2: ...m air conditioner English Operation manual Daikin room air conditioner CTXM15R2V1B CTXM15R5V1B FTXM20R2V1B FTXM20R5V1B FTXM25R2V1B FTXM25R5V1B FTXM35R2V1B FTXM35R5V1B FTXM42R2V1B FTXM42R5V1B FTXM50R2V...

Page 3: ...eless LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving an...

Page 4: ...orted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are...

Page 5: ...gerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odour...

Page 6: ......

Page 7: ...ndoor unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 8: ...high low off 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the...

Page 9: ...ion mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be set as fo...

Page 10: ...l automatic swing is selected Comfort airflow operation will be cancelled 5 5 2 Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and te...

Page 11: ...e Econo operation can be only set when the unit is running Pressing cancels the setting and disappears from the LCD Note remains on the LCD even if you turn off the unit using the user interface or in...

Page 12: ......

Page 13: ...displayed on the LCD 5 10 Weekly timer operation With this operation you can save up to 4 timer settings for each day of the week Example Create a different setting from Monday to Friday and a differ...

Page 14: ...cted day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will be copied 4 Press or to select the...

Page 15: ...3 Follow the directions on the screen to install 5 11 3 To set the wireless connection There are two options to connect the wireless adapter with your smart device Connect the wireless LAN to your sma...

Page 16: ...y default in case you want to disconnect the wireless LAN and the communication device e g router or smart device repeat the setting if the connection was unsuccessful 1 On home screen menu hold for a...

Page 17: ...orinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 NOTICE Applicable legislation on fluorinated greenhouse gases requires that...

Page 18: ......

Page 19: ...it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult to remove stains use water or a neutral dete...

Page 20: ...lter and the silver allergen removal air purifying filter contact your dealer Item Part number Titanium deodorising filter 1 set KAF970A46 Silver allergen removal air purifying filter 1 set KAF057A41...

Page 21: ...tems it is impossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date poss...

Page 22: ......

Page 23: ......