background image

8 Troubleshooting

Operation manual

16

FTXM20~4 FTXM20~71R2V1B

Daikin room air conditioner

3P485919-11S – 2020.06

7.6

To clean the titanium apatite
deodorising filter and the silver
allergen removal air purifying filter

INFORMATION

Clean the filter with water every 6 months.

1

Remove:

for class 15~42:

 silver allergen removal air purifying filter from the

tabs

for  class  50~71:

  titanium  apatite  deodorising  filter  and  the  silver

allergen removal air purifying filter from all 4 claws.

a

Claw

2

Remove the dust from the filter with a vacuum cleaner.

3

Soak the filter for 10 to 15 minutes in warm water.

Note: 

 

(class 50~71)

 Do NOT remove the filter from the frame.

Class 15~42

Class 50~71

4

After washing, shake off remaining water and dry the filter in the
shade. Do NOT wring out the filter when removing water.

7.7

To replace the titanium apatite
deodorising filter and the silver
allergen removal air purifying filter

INFORMATION

Replace the filter every 3 years.

1

Remove  the  filter  from  the  tabs  (class  15~42)  or  frame  (class
50~71) and replace the filter with a new one.

Class 15~42

Class 50~71

INFORMATION

▪ Do NOT throw away the filter frame, but use it again.

▪ Dispose of the old filter as non-flammable waste.

To  order  titanium  apatite  deodorising  filter  and  the  silver  allergen
removal air purifying filter, contact your dealer.

Item

Part number

Titanium deodorising filter - 1 set KAF970A46

Silver allergen removal air
purifying filter - 1 set

KAF057A41

7.8

To re-install the front panel

1

Attach the front panel. Align the shafts with the slots and push
them all the way in.

2

Close  the  front  panel  slowly;  press  at  both  sides  and  at  the
centre.

8

Troubleshooting

If one of the following malfunctions occur, take the measures shown
below and contact your dealer.

WARNING

Stop  operation  and  shut  off  the  power  if  anything
unusual occurs (burning smells etc.).

Leaving  the  unit  running  under  such  circumstances  may
cause breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person.

Malfunction

Measure

If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does NOT properly work.

Turn OFF the main power
switch.

If water leaks from the unit.

Stop the operation.

The operation switch does NOT work
well.

Turn OFF the power
supply.

The operation lamp flashes and you can
check the error code by the user
interface. To display the error code see
the user reference guide.

Notify your installer and
report the error code.

If  the  system  does  NOT  operate  properly  except  for  the  above
mentioned cases and none of the above mentioned malfunctions is
evident,  investigate  the  system  in  accordance  with  the  following
procedures.

Summary of Contents for FTXM71R Series

Page 1: ...EN Daikin Perfera FTXM71R RXM71R...

Page 2: ...m air conditioner English Operation manual Daikin room air conditioner CTXM15R2V1B CTXM15R5V1B FTXM20R2V1B FTXM20R5V1B FTXM25R2V1B FTXM25R5V1B FTXM35R2V1B FTXM35R5V1B FTXM42R2V1B FTXM42R5V1B FTXM50R2V...

Page 3: ...eless LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving an...

Page 4: ...orted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are...

Page 5: ...gerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odour...

Page 6: ......

Page 7: ...ndoor unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 8: ...high low off 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the...

Page 9: ...ion mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be set as fo...

Page 10: ...l automatic swing is selected Comfort airflow operation will be cancelled 5 5 2 Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and te...

Page 11: ...e Econo operation can be only set when the unit is running Pressing cancels the setting and disappears from the LCD Note remains on the LCD even if you turn off the unit using the user interface or in...

Page 12: ......

Page 13: ...displayed on the LCD 5 10 Weekly timer operation With this operation you can save up to 4 timer settings for each day of the week Example Create a different setting from Monday to Friday and a differ...

Page 14: ...cted day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will be copied 4 Press or to select the...

Page 15: ...3 Follow the directions on the screen to install 5 11 3 To set the wireless connection There are two options to connect the wireless adapter with your smart device Connect the wireless LAN to your sma...

Page 16: ...y default in case you want to disconnect the wireless LAN and the communication device e g router or smart device repeat the setting if the connection was unsuccessful 1 On home screen menu hold for a...

Page 17: ...orinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 NOTICE Applicable legislation on fluorinated greenhouse gases requires that...

Page 18: ......

Page 19: ...it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult to remove stains use water or a neutral dete...

Page 20: ...lter and the silver allergen removal air purifying filter contact your dealer Item Part number Titanium deodorising filter 1 set KAF970A46 Silver allergen removal air purifying filter 1 set KAF057A41...

Page 21: ...tems it is impossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date poss...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 11S 2020 06 Copyright 2...

Page 26: ......

Reviews: