background image

6 Energy saving and optimum operation

Operation manual

13

FTXM20~4 FTXM20~71R2V1B
Daikin room air conditioner
3P485919-11S – 2020.06

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu 

  by  pressing 

  once  or 

repeatedly.

(5 sec.) 

3

Press 

 to confirm the selection.

Result: 

 is blinking. The timer LED is blinking in 0.5 s interval

and the operation LED is off.

4

Press  the  WPS  button  on  your  communication  device  (e.g.
router)  within  approximately  1  minute.  Refer  to  the  manual  of
your communication device.

Result: 

If  the  connection  to  your  communication  device  is

successful,  the  timer  LED  is  blinking  in  1.0  s  interval  and  the
operation LED is off.

INFORMATION

If  the  connection  with  your  router  is  not  possible,  try
procedure 

"To 

connect 

using 

SSID 

and 

KEY

number" 

[

4

 13].

5

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To connect using SSID and KEY number

1

On  home  screen  menu,  hold 

  for  at  least  5  seconds  while

the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu 

  by  pressing 

  twice  or 

repeatedly.

(5 sec.) 

3

Press 

 to confirm the selection.

Result: 

  is  blinking.  The  timer  LED  and  operation  LED  are

blinking simultaneously.

4

Open  the  Daikin  Residential  Controller  application  on  your
smart device and follow the steps on the screen.

Result: 

If the connection to your smart device is successful, the

timer LED is blinking in 1.0 s interval and the operation LED is
off.

5

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To reset the connection setting to the factory
default

Reset the connection setting to the factory default in case you want
to:

▪ disconnect  the  wireless  LAN  and  the  communication  device  (e.g.

router) or smart device,

▪ repeat the setting if the connection was unsuccessful.

1

On  home  screen  menu,  hold 

  for  at  least  5  seconds  while

the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu    by  pressing 

  twice  or 

repeatedly.

(5 sec.) 

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

 is blinking. The operation and timer LEDs are blinking

at  the  same  time  in  1  s  interval.  The  setting  is  reset  to  the
factory default.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

To turn off the wireless LAN connection

If you want to turn off the wireless connection function:

1

On home screen menu, press 

 for at least 5 seconds while

the unit is not operating.

Result: 

The SP menu   appears.   is blinking.

2

Change  to  the  SP  menu 

  by  pressing 

  once  or 

repeatedly.

(5 sec.) 

3

Hold 

 for at least 2 seconds to confirm the selection.

Result: 

  is  blinking.  The  operation  and  timer  LEDs  are

blinking alternately in 1 s interval. Communication is OFF.

4

Press 

 to exit the menu.

Result: 

The display will return to the default screen.

6

Energy saving and optimum
operation

INFORMATION

▪ Even if the unit is turned OFF, it consumes electricity.

▪ When the power turns back on after a power break, the

previously selected mode will be resumed.

CAUTION

NEVER  expose  little  children,  plants  or  animals  directly  to
the airflow.

WARNING

Do NOT place objects below the indoor and/or outdoor unit
that  may  get  wet.  Otherwise  condensation  on  the  unit  or
refrigerant pipes, air filter dirt or drain blockage may cause
dripping,  and  objects  under  the  unit  may  get  dirty  or
damaged.

WARNING

Do  NOT  place  a  flammable  spray  bottle  near  the  air
conditioner and do NOT use sprays near the unit. Doing so
may result in a fire.

Summary of Contents for FTXM71R Series

Page 1: ...EN Daikin Perfera FTXM71R RXM71R...

Page 2: ...m air conditioner English Operation manual Daikin room air conditioner CTXM15R2V1B CTXM15R5V1B FTXM20R2V1B FTXM20R5V1B FTXM25R2V1B FTXM25R5V1B FTXM35R2V1B FTXM35R5V1B FTXM42R2V1B FTXM42R5V1B FTXM50R2V...

Page 3: ...eless LAN connection 12 5 11 1 Precautions when using the wireless LAN 12 5 11 2 To install the Daikin Residential Controller application 12 5 11 3 To set the wireless connection 12 6 Energy saving an...

Page 4: ...orted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are...

Page 5: ...gerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odour...

Page 6: ......

Page 7: ...ndoor unit display ON OFF a b c d e a Signal receiver for user interface b Operation lamp c Timer lamp d Intelligent eye lamp e ON OFF button ON OFF button If the user interface is missing you can use...

Page 8: ...high low off 4 5 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and close to set the reference position 5 Operation 5 1 Operation range Use the...

Page 9: ...ion mode Drying Operation mode Cooling Operation mode Heating Operation mode Fan only Shows the set temperature 1 Press one or more times to select the operation mode Result The mode will be set as fo...

Page 10: ...l automatic swing is selected Comfort airflow operation will be cancelled 5 5 2 Intelligent eye operation The system detects movement in the room and automatically adjusts the airflow direction and te...

Page 11: ...e Econo operation can be only set when the unit is running Pressing cancels the setting and disappears from the LCD Note remains on the LCD even if you turn off the unit using the user interface or in...

Page 12: ......

Page 13: ...displayed on the LCD 5 10 Weekly timer operation With this operation you can save up to 4 timer settings for each day of the week Example Create a different setting from Monday to Friday and a differ...

Page 14: ...cted day of the week will be copied 1 Press 2 Press or to select the day of the week to be copied 3 Press Result The reservation of the selected day of the week will be copied 4 Press or to select the...

Page 15: ...3 Follow the directions on the screen to install 5 11 3 To set the wireless connection There are two options to connect the wireless adapter with your smart device Connect the wireless LAN to your sma...

Page 16: ...y default in case you want to disconnect the wireless LAN and the communication device e g router or smart device repeat the setting if the connection was unsuccessful 1 On home screen menu hold for a...

Page 17: ...orinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 NOTICE Applicable legislation on fluorinated greenhouse gases requires that...

Page 18: ......

Page 19: ...it is difficult to remove stains use water or a neutral detergent 7 3 To clean the front panel 1 Clean the front panel with a soft cloth If it is difficult to remove stains use water or a neutral dete...

Page 20: ...lter and the silver allergen removal air purifying filter contact your dealer Item Part number Titanium deodorising filter 1 set KAF970A46 Silver allergen removal air purifying filter 1 set KAF057A41...

Page 21: ...tems it is impossible to fix the problem yourself contact your installer and state the symptoms the complete model name of the unit with manufacturing number if possible and the installation date poss...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 3P485919 11S 2020 06 Copyright 2...

Page 26: ......

Reviews: