Installation of outdoor unit
Installation of indoor / outdoor unit
43
2
C: 3PA60114-14Y
3
English
This air conditioner is an appliance that should not be
•
accessible to the general public.
The wall thickness of fi eld-installed pipes should be
•
selected in accordance with the relevant local, state,
and national regulations.
〈
./4%
〉
The PCI Data Station is a class A product. In a domestic
environment this product may cause radio interference in
which case the user may be required to take adequate mea-
sures.
INTRODUCTION
2.
Standard
/
peration
,
imit
2-1
The fi gures below assume following operating conditions for
indoor and outdoor units:
Equivalent pipe length ................ 25 ft.
Level difference .......................... 0 ft.
Cool
i
ng
Heat
i
ng
<
b
>
B
<c>
A
C
D
<
a
>
0
5
59
115
41
50
50
4
3
70
95
81
50
2
3
77
60
67
82
57
A Outdoor temperature (°FDB)
B Indoor temperature (°FWB)
C Outdoor temperature (°FWB)
D Indoor temperature (°FDB)
Range for continuous operation
Range for pull down operation
Range for warming up operation
Range for operation
Technical specifi cations
2-2
∗
<a> and
∗
<b> in the table indicate the operating condition
(shown i
NTHE
3TANDARD/PERATION,IMIT
fi gure
TOLEFT
.)
M
odel
R
ZQ
18P
VJU
R
ZQ
24P
VJU
.OTE
Refr
igerant
R410
A
P
ower
208
/
230
V
60
Hz
[FAQ] W
all mounted
Cooling
(MB
h
)
∗
<a>
Heating
(MB
h
)
∗
<b>
[F
C
Q]
Ceiling
mounted
Cooling
(MB
h
)
∗
<a>
Heating
(MB
h
)
∗
<b>
[F
H
Q]
Ceiling
Suspended
Cooling
(MB
h
)
∗
<a>
Heating
(MB
h
)
∗
<b>
[F
T
Q] A
ir
Handling
Unit
Cooling
(MB
h
)
Heating
(MB
h
)
18
20
18
20
18
20
18
20
24
26
24
27
24
27
24
26
∗
<a>
∗
<b>
Dimensions
(inch)
30-5
/
16
×
35
7
/
16
×
12
5
/
8
H
× W ×
D
W
eight
(lb.)
150
Connections
G
as
(inch)
5
/
8
Liquid
(inch)
3
/
8
E
lectrical
specifi
cations
2-
3
∗
<c>
in
the
table
indicate
the
operating
condition
(shown
in
the
3TANDARD/PERATION,IMIT
figure
TOLEFT
).
M
odel
R
ZQ
18P
VJU
R
ZQ
24P
VJU
.OTE
P
ower
Phase
~
Frequency
(
Hz
)
60
V
oltage
(
V
)
208
/
230
V
oltage
torerance
(
%
)
±
10
M
a
x
.Overcurrent
protective
device
(A)
20
Compressor
Phase
3
~
Frequency
(
Hz
)
60
V
oltage
(
V
)
208
/
230
M
in.
Circuit
Amps.
(A)
16.5
∗
<c>
A
ccessories
2-
4
Confirm
that
the
following
accessories
are
supplied.
Clamp
Insulation tube
Cover
(
H
andle)
(Large-1) (Large-2) (Small-1) (Small-2)
(1 pc.)
(2 pcs.)
(1 pc.)
(2 pcs.)
(1 pc.)
Screw
Conduit mounting plate
Others
Installation manual
•
(1 pc.)
(2 pcs.)
(2 pcs.)
Summary of Contents for FTQ-PA
Page 1: ...EDUS281008 Split System Air Conditioners Air Handling Unit FTQ PA RZQ P9 ...
Page 12: ...EDUS281008 Dimensions and service space FTQ PA RZQ P 9 1 3D06421 ...
Page 15: ...Piping diagrams EDUS281008 12 FTQ PA RZQ P 5 2 Outdoor unit RZQ18PVJU9 RZQ24PVJU9 3D062238B ...
Page 20: ...EDUS281008 Electrical characteristics FTQ PA RZQ P 17 1 7 2 Electric heater ...