![background image](http://html1.mh-extra.com/html/daikin/ftkn09nmvju/ftkn09nmvju_service-manual_3296451068.webp)
Service Diagnosis
SiUS041501E
57
Service Diagnosis
3. Service Diagnosis
Method 1
1. When the
TIMER CANCEL
button is held down for 5 seconds,
00
is displayed on the
temperature display screen.
2. Press the
TIMER CANCEL
button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the
TIMER CANCEL
button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
(
→
Refer to page 58.)
No.
Code
No.
Code
No.
Code
1
00
16
A3
31
UF
2
A5
17
H8
32
UH
3
E7
18
H9
33
P4
4
F3
19
C9
34
H7
5
F6
20
CC
35
U2
6
L3
21
C4
36
EA
7
L4
22
C5
37
AH
8
L5
23
J3
38
FA
9
U4
24
J6
39
E8
10
E6
25
J8
40
CH
11
H6
26
E5
41
J9
12
H0
27
A1
42
E3
13
A6
28
E1
43
H3
14
U0
29
UA
15
C7
30
U3
<ARC480 Series>
TIMER CANCEL
button
(R21665)
Summary of Contents for FTKN09NMVJU
Page 12: ...SiUS041501E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 59: ...SiUS041501E Remote Controller 48 Part 5 Remote Controller 1 Cooling Only 49 2 Heat Pump 51...
Page 65: ...SiUS041501E Service Diagnosis 54 5 13 Power Module Check 100...
Page 132: ...Revision History Month Year Version Revised contents 03 2015 SiUS041501E First edition...