![background image](http://html1.mh-extra.com/html/daikin/ftkn09nmvju/ftkn09nmvju_service-manual_3296451125.webp)
SiUS041501E
Piping Diagrams
Appendix
114
RKN24NMVJU
RK24NMVJU
OUTDOOR UNIT
HEAT EXCHANGER
M
1/4 CuT
MUFFLER
1/4 CuT
MUFFLER
1/2 CuT
ACCUMULATOR
COMPRESSOR
REFRIGERANT FLOW
COOLING
FIELD PIPING
(1/4 CuT)
FIELD PIPING
(5/8 CuT)
GAS STOP VALVE
WITH SERVICE PORT
LIQUID
STOP VALVE
STRAINER
LIQUID
RECEIVER
ELECTRONIC
EXPANSION
VALVE
MUFFLER
WITH
FILTER
1/4 CuT
1/4 CuT
CAPILLARY TUBE 1
5/32 CuT
CAPILLARY TUBE 2
5/32 CuT
PROPELLER FAN
OUTDOOR AIR
THERMISTOR
HEAT EXCHANGER
THERMISTOR
1/2 CuT
1/2 CuT
1/2 CuT
9/32 CuT
9/32 CuT
9/32 CuT
1/2 CuT
9/32 CuT
5/16 CuT
5/16 CuT
DISCHARGE PIPE
THERMISTOR
FOUR WAY
VALVE
3D092223
OUTDOOR UNIT
MUFFLER
MUFFLER
ACCUMULATOR
COMPRESSOR
FIELD PIPING
(1/4 CuT)
FIELD PIPING
(5/8 CuT)
REFRIGERANT FLOW
COOLING
1/4 CuT
1/2 CuT
GAS STOP VALVE
WITH SERVICE PORT
LIQUID
STOP VALVE
1/4 CuT
STRAINER
LIQUID
RECEIVER
ELECTRONIC
EXPANSION
VALVE
MUFFLER
WITH
FILTER
HEAT EXCHANGER
5/32 CuT
5/32 CuT
5/32 CuT
1/4 CuT
1/4 CuT
CAPILLARY TUBE 1
CAPILLARY TUBE 2
CAPILLARY TUBE 3
OUTDOOR AIR
THERMISTOR
9/32 CuT
9/32 CuT
9/32 CuT
9/32 CuT
1/2 CuT
9/32 CuT
9/32 CuT
M
PROPELLER FAN
1/2 CuT
1/2 CuT
1/2 CuT
HEAT EXCHANGER
THERMISTOR
FOUR WAY
VALVE
5/16 CuT
5/16 CuT
DISCHARGE PIPE
THERMISTOR
3D092250
Summary of Contents for FTKN09NMVJU
Page 12: ...SiUS041501E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 59: ...SiUS041501E Remote Controller 48 Part 5 Remote Controller 1 Cooling Only 49 2 Heat Pump 51...
Page 65: ...SiUS041501E Service Diagnosis 54 5 13 Power Module Check 100...
Page 132: ...Revision History Month Year Version Revised contents 03 2015 SiUS041501E First edition...