![background image](http://html1.mh-extra.com/html/daikin/ftkn09nmvju/ftkn09nmvju_service-manual_3296451117.webp)
SiUS041501E
Field Settings
Trial Operation and Field Settings
106
3.2
When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different addresses.
Procedure
(1) Remove the battery cover of the remote controller.
(2) Cut the address jumper.
(3) Press the center of the
TEMP
button and the
OFF
button on the remote controller at the same
time.
(4) Select
A
(address setting) with the
TEMP
or
TEMP
button.
(5) Press the
FAN
button to enter the address setting mode.
→
The indoor unit operation lamp blinks for 1 minute.
(6) Press the indoor unit
ON/OFF
button while the operation lamp is blinking.
(7) Press the
FAN
button on the remote controller for 5 seconds to return to the normal mode.
Address
EXIST
Jumper
CUT
1
2
(R21071)
Jumper
(R21822)
(R21072)
ON/OFF
OPERATION lamp