![background image](http://html1.mh-extra.com/html/daikin/ftkn09nmvju/ftkn09nmvju_service-manual_3296451070.webp)
Service Diagnosis
SiUS041501E
59
Service Diagnosis
5. Diagnose by the sound.
beep: The left-side number does not correspond with the error code.
two consecutive beeps: The left-side number corresponds with the error code but the right-
side number does not.
long beep: Both the left-side and right-side numbers correspond with the error code.
(The numbers indicated when you hear the long beep are the error code.
→
Refer to page 60.)
6. Press the
FAN
button.
The right-side number blinks.
7. Press the
TEMP
or
TEMP
button
and change the number until you hear the long beep.
8. Diagnose by the sound.
beep: The left-side number does not correspond with the error code.
two consecutive beeps: The left-side number corresponds with the error code but the right-
side number does not.
long beep: Both the left-side and right-side numbers correspond with the error code.
9. Determine the error code.
The numbers indicated when you hear the long beep are the error code.
Error codes and description
→
Refer to page 60.
10.Press the
FAN
button for 5 seconds to exit from the service check mode.
(When the remote controller is left untouched for 60 seconds, it returns to the normal mode
also.)
(R21667)
(R21063)
(R21668)
(R21667)
Summary of Contents for FTKN09NMVJU
Page 12: ...SiUS041501E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 59: ...SiUS041501E Remote Controller 48 Part 5 Remote Controller 1 Cooling Only 49 2 Heat Pump 51...
Page 65: ...SiUS041501E Service Diagnosis 54 5 13 Power Module Check 100...
Page 132: ...Revision History Month Year Version Revised contents 03 2015 SiUS041501E First edition...