Piping Diagrams
SiUS041501E
115
Appendix
1.2.2 Heat Pump
RXN09NMVJU, RX09NMVJU
RXN12NMVJU, RX12NMVJU
OUTDOOR UNIT
HEAT EXCHANGER
9/32 CuT
9/32 CuT
1/4 CuT
1/4 CuT
9/32 CuT
M
PROPELLER FAN
3/8 CuT
3/8 CuT
3/16 CuT
3/8 CuT
5/16 CuT
MUFFLER
3/8 CuT
3/8 CuT
REFRIGERANT FLOW
5/16 CuT
ACCUMULATOR
MUFFLER
COOLING
HEATING
COMPRESSOR
3D092244
FIELD PIPING
(1/4 CuT)
FIELD PIPING
(3/8 CuT)
GAS STOP VALVE
WITH SERVICE PORT
LIQUID STOP
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MOTOR
OPERATED
VALVE
HEAT EXCHANGER
THERMISTOR
FOUR WAY
VALVE
ON: HEATING
DISCHARGE PIPE
THERMISTOR
OUTDOOR TEMPERATURE
THERMISTOR
OUTDOOR UNIT
HEAT EXCHANGER
9/32 CuT
9/32 CuT
3/8 CuT
3/16 CuT
1/4 CuT
1/4 CuT
3/16 CuT
M
PROPELLER FAN
3/8 CuT
3/8 CuT
3/16 CuT
3/8 CuT
5/16 CuT
MUFFLER
3/8 CuT
3/8 CuT
REFRIGERANT FLOW
5/16 CuT
ACCUMULATOR
MUFFLER
COOLING
HEATING
COMPRESSOR
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MOTOR
OPERATED
VALVE
MUFFLER
WITH
FILTER
FOUR WAY
VALVE
ON: HEATING
LIQUID STOP
VALVE
GAS STOP VALVE
WITH SERVICE PORT
FIELD PIPING
(1/4 CuT)
FIELD PIPING
(3/8 CuT)
DISCHARGE PIPE
THERMISTOR
MUFFLER
WITH
FILTER
3D092207
Summary of Contents for FTKN09NMVJU
Page 12: ...SiUS041501E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 59: ...SiUS041501E Remote Controller 48 Part 5 Remote Controller 1 Cooling Only 49 2 Heat Pump 51...
Page 65: ...SiUS041501E Service Diagnosis 54 5 13 Power Module Check 100...
Page 132: ...Revision History Month Year Version Revised contents 03 2015 SiUS041501E First edition...