For RXD50·60·71J
SiBE04-101
146
Removal Procedure
2
There is one nut for the
compressor.
3
Remove the nut with
spanner.
Before taking this
procedure, make sure there
is no refrigerant gas left in
the refrigerant pipes.
Warning
The compressor's refrigerating
machine oil may catch fire. Have
wet cloth at hand for quickly putting
out the fire.
Warning
If refrigerant gas leaks during the
job, ventilate the room. (Bear in
mind that if the refrigerant gas is
exposed to open flames, noxious
gas may be generated.)
Caution
Be careful not to get yourself burnt
with the pipes and other parts that
are heated by the gas welding rod.
When heating up the
brazed parts, make sure to
carry out the N
2
replacement.
1
Disconnect the brazed
section of the discharge
pipe.
2
Disconnect the brazed
section of the suction pipe.
3
Dismount the compressor.
Step
Procedure
Points
SiBE04-101.book Page 146 Monday, October 15, 2001 3:08 PM