![Daikin FLX50JV1B User Manual Download Page 40](http://html1.mh-extra.com/html/daikin/flx50jv1b/flx50jv1b_user-manual_2459284040.webp)
General Functions
SiBE04-101
32
Main Function
1.11
Inverter Powerful Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by increasing
the indoor fan rotating speed and the compressor frequency.
Details of the
Control
When the powerful operation switch is pressed in each operation mode, the fan rotating speed and set
temperature become as follows for 20 min.
Ex.) Powerful operation in cooling mode
Operation Mode
Fan rotating speed
Target set temperature
Cooling
H tap + 80rpm
18˚C
Dry
Dry rotating speed + 80-120rpm
Normally, target temperature in dry
operation - Approx. 2˚C
Heating
H tap + 80rpm
30˚C
Fan (Cooling Only
Type)
H tap + 80rpm
—
Automatic (Heat
Pump Type)
Same as cooling/heating powerful
operation
Target is not changed.
Cooling
Fan Tap
50 Class
(Wall Mounted
Type)
60 Class
(Wall Mounted
Type)
71 Class
(Wall Mounted
Type)
50 Class
(Floor/Ceiling
Type)
60 Class
(Floor/Ceiling
Type)
LLL (W1)
350
350
350
300
300
LL (W2)
650
650
650
400
400
←
Thermostat
off is LL
L (W3C)
1020
1100
1100
1020
1100
ML (W4C)
1090
1170
1180
1090
1170
M (W5C)
1170
1240
1270
1170
1240
MH (W6C)
1240
1310
1360
1240
1310
H (W7)
1320
1380
1450
1320
1380
Poweerful
1400
1460
1530
1400
1460
Heating
Fan Tap
50 Class
Heating
60 Class
Heating
71 Class
Heating
50 Class
(Floor/Ceiling
Type)
60 Class
(Floor/Ceiling
Type)
LLL (W1)
350
350
350
300
300
←
Thermostat
off is LLL
LL (W2)
650
650
650
400
400
L (W3W)
960
1000
1000
860
940
ML (W4W)
1040
1090
1110
960
1030
M (W5W)
1120
1190
1220
1060
1130
MH (W6W)
1200
1280
1330
1160
1220
H (W8)
1280
1380
1450
1260
1320
Poweerful
1360
1460
1530
1340
1400
(R1167)
Target temp.
Fan
80rpm
Set temp.
18˚C
Powerful ON
Powerful OFF
H tap
Set tap
It should be the lower limit of cooling temperature.
It counts 20 min. also in the remote controller.
Ending condition: "or" in 1 to 3
1. TPF ends.
2. Stop
3. Powerful operation is OFF.
20min.
SiBE04-101.book Page 32 Monday, October 15, 2001 3:08 PM