![background image](http://html1.mh-extra.com/html/daikin/flx50jv1b/flx50jv1b_user-manual_2459284061.webp)
SiBE04-101
Instruction
System Configuration
53
9
Preparation Before Operation
■
■
■
■
■
Setting the air purifying filters
Indoor unit
●
Holding down (
) or (
) button
rapidly increases or decreases the time display.
NOTE
■
■
■
■
■
Setting the clock
Press
.
Press
to set the clock to the
present time.
■
■
■
■
■
Turn the breaker ON
●
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
Pull out the air filters.
●
Push upwards the
tab at the center of
each air filter, then
pull it down.
2
Open the front grille.
●
Hold the grille by the tabs on the two sides
and lift it until it stops with a click.
(about 60˚)
1
ûC
Set the air purifying filters.
●
Attach an air purifying filter to each air filter.
(See page 16 “Care and cleaning”)
Set the air filters in their original
positions and close the front grille.
●
Operation without air filters may result in
troubles as dust will accumulate inside the
indoor unit.
3
4
1
is displayed.
2
blinks.
3
Please note
●
The air conditioner always consumes 15 – 35 watts of
electricity even while it is not operating.
●
If you are not going to use the air conditioner for a long period,
for example in spring or autumn, turn the breaker OFF.
●
Use the air conditioner in the following conditions.
Press
.
blinks.
(Now the clock is set.)
Mode
COOL/
DRY
HEAT
Operating conditions
Outdoor temperature
RXD: –10 to 46 ˚C
2~3MX
: 21 to 43 ˚C
4MX
: 10 to 43 ˚C
Indoor temperature
: 15 to 28 ˚C
Indoor humidity
: 80% max. (*1)
Outdoor temperature
RXD: –15 to 24 ˚C
2~4MX
: –10 to 24 ˚C
Indoor temperature
: 10 to 30 ˚C
If operation is continued out of this range
•
A safety device may work to stop the
operation.
(In multi system, it may work to stop
the operation of the outdoor unit only.)
•
Condensation may occur on the
indoor unit and drip.
•
A safety device may work to stop the
operation.
(*1) Use in humidity 60% or lower when using the unit
at an outdoor temperature of 10˚C or lower.
Tips for saving energy
●
Be careful not to cool the room too much.
Keeping the temperature setting at a
moderate level helps save energy.
Recommended temperature setting
For cooling: 26˚C – 28˚C
For heating: 20˚C – 24˚C
●
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling effect.
●
Clogged air filters cause inefficient
operation and waste energy. Clean them
once in about every two weeks.
SiBE04-101.book Page 53 Monday, October 15, 2001 3:08 PM