background image

Table of Contents

Installation and operation manual

4

FDA125A5VEB

Split system air conditioners

4P494410-1D – 2022.10

Table of Contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 Specific installer safety instructions

5

For the user

6

3 User safety instructions

6

3.1

General......................................................................................

6

3.2

Instructions for safe operation ...................................................

7

4 About the system

9

4.1

System layout ............................................................................

9

5 User interface

9

6 Operation

9

6.1

Operation range ........................................................................

9

6.2

About operation modes .............................................................

10

6.2.1

Basic operation modes ............................................... 10

6.2.2

Special heating operation modes................................ 10

6.3

To operate the system...............................................................

10

7 Maintenance and service

10

7.1

Precautions for maintenance and service .................................

10

7.2

Cleaning the air filter and air outlet............................................

10

7.2.1

To clean the air filter ................................................... 10

7.2.2

To clean the air outlet ................................................. 11

7.3

About the refrigerant..................................................................

11

8 Troubleshooting

11

9 Relocation

12

10 Disposal

12

For the installer

12

11 About the box

12

11.1

Indoor unit .................................................................................

12

11.1.1

To remove the accessories from the indoor unit......... 12

12 Unit installation

12

12.1

Preparing the installation site ....................................................

12

12.1.1

Installation site requirements of the indoor unit .......... 12

12.2

Mounting the indoor unit............................................................

13

12.2.1

Guidelines when installing the indoor unit................... 13

12.2.2

Guidelines when installing the ducting........................ 14

12.2.3

Guidelines when installing the drain piping................. 14

13 Piping installation

16

13.1

Preparing refrigerant piping .......................................................

16

13.1.1

Refrigerant piping requirements.................................. 16

13.1.2

Refrigerant piping insulation ....................................... 16

13.2

Connecting the refrigerant piping ..............................................

16

13.2.1

To connect the refrigerant piping to the indoor unit .... 16

14 Electrical installation

17

14.1

Specifications of standard wiring components ..........................

17

14.2

To connect the electrical wiring to the indoor unit .....................

17

15 Commissioning

18

15.1

Checklist before commissioning ................................................

19

15.2

To perform a test run .................................................................

19

16 Configuration

19

16.1

Field setting ...............................................................................

19

17 Technical data

20

17.1

Wiring diagram ........................................................................... 20

17.1.1

Unified wiring diagram legend...................................... 20

1

About the documentation

1.1

About this document

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied  materials  follow  the  instructions  from  Daikin
(including  all  documents  listed  in  “Documentation  set”)
and, in addition, comply with applicable legislation and are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised inst end users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation and operation manual:

▪ Installation and operation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer and user reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

https://www.daikin.eu

.  Use  the  search

function   to find your model.

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

Scan the QR code below to find the full documentation set and more
information about your product on Daikin website.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

Summary of Contents for FDA125A5VEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FDA125A5VEB...

Page 2: ...j atbilst d m direkt v m vai regul m ja vien ie izstr d jumi tiek lietoti saska ar m su instrukcij m s v zhode s nasleduj cou imi smernicou ami alebo predpisom mi za predpokladu e sa v robky pou vaj v...

Page 3: ...s amended S I 2008 1597 Supply of Machinery Safety Regulations 2008 S I 2016 1101 Electrical Equipment Safety Regulations 2016 S I 2016 1091 Electromagnetic Compatibility Regulations 2016 following th...

Page 4: ...ical data 20 17 1 Wiring diagram 20 17 1 1 Unified wiring diagram legend 20 1 About the documentation 1 1 About this document WARNING Make sure installation servicing maintenance repair and applied ma...

Page 5: ...xternal static pressure for the unit Refer to the technical datasheet of your model for the setting range Make sure to install the canvas duct so vibrations are NOT transmitted to the duct or ceiling...

Page 6: ...and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children SHALL NOT play with the appliance Cleaning...

Page 7: ...t is unhealthy to expose your body to the air flow for a long time CAUTION To avoid oxygen deficiency ventilate the room sufficiently if equipment with burner is used together with the system CAUTION...

Page 8: ...in this unit is mildly flammable Refer to the outdoor unit specifications for the type of refrigerant to be used WARNING The appliance using R32 refrigerant shall be stored so as to prevent mechanical...

Page 9: ...ce CAUTION NEVER touch the internal parts of the controller Do NOT remove the front panel Some parts inside are dangerous to touch and appliance problems may happen For checking and adjusting the inte...

Page 10: ...eration During defrost operation the indoor unit fan will stop operation and the following icon will appear on the home screen The system will resume normal operation after approximately 6 to 8 minute...

Page 11: ...efrigerant if applicable in this unit is mildly flammable Refer to the outdoor unit specifications for the type of refrigerant to be used WARNING The appliance using R32 refrigerant shall be stored so...

Page 12: ...igerant if applicable in this unit is mildly flammable Refer to the outdoor unit specifications for the type of refrigerant to be used 11 1 1 To remove the accessories from the indoor unit 16 8 1 1 3...

Page 13: ...nside of the unit 4 Reinstall the interchangeable plate When installing an air inlet duct select fixing screws that stick out 5 mm on the inside of the flange to protect the air filter from damage dur...

Page 14: ...ation insulation rubber to the hanging bolts When welding make sure NOT to spatter onto the drain pan or the air filter If the metal duct passes through a metal lath wire lath or metal plate of the wo...

Page 15: ...eld supply d Hanging bars field supply Combining drain pipes You can combine drain pipes Make sure to use drain pipes and T joints with the correct gauge for the operating capacity of the units 100 62...

Page 16: ...ompliant with the latest version of ISO14903 can be used NOTICE The piping and other pressure containing parts shall be suitable for refrigerant Use phosphoric acid deoxidised seamless copper for refr...

Page 17: ...at is regularly turned ON and OFF by the utility 14 1 Specifications of standard wiring components NOTICE We recommend using solid single core wires If stranded wires are used slightly twist the stran...

Page 18: ...at the interface point between the user s supply and the public system EN IEC 61000 3 12 European International Technical Standard setting the limits for harmonic currents produced by equipment conne...

Page 19: ...est run is only completed if there is no malfunction code displayed on the user interface See the service manual for the complete list of error codes and a detailed troubleshooting guideline for each...

Page 20: ...represented in the overview below by in the part code Symbol Meaning Symbol Meaning Circuit breaker Protective earth Connection Protective earth screw Connector A Rectifier Symbol Meaning Symbol Meani...

Page 21: ...stor R T Thermistor RC Receiver S C Limit switch S L Float switch S NG Refrigerant leak detector S NPH Pressure sensor high S NPL Pressure sensor low S PH HPS Pressure switch high S PL Pressure switch...

Page 22: ......

Page 23: ......

Page 24: ...4P494410 1D 2022 10 Copyright 2017 Daikin Verantwortung f r Energie und Umwelt...

Reviews: