9 Relocation
Installation and operation manual
12
FDA125A5VEB
Split system air conditioners
4P494410-1D – 2022.10
Malfunction
Measure
If the user interface displays
.
Notify your installer and
report the error code. To
display an error code see
the reference guide of the
user interface.
INFORMATION
Refer to the reference guide located on
for more troubleshooting tips. Use the
search function to find your model.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
9
Relocation
Contact your dealer to remove and reinstall the entire unit. Moving
units requires technical expertise.
10
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
For the installer
11
About the box
11.1
Indoor unit
INFORMATION
The following figures are just examples and may NOT
completely match your system layout.
WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly
flammable. Refer to the outdoor unit specifications for the
type of refrigerant to be used.
11.1.1
To remove the accessories from the
indoor unit
16×
8×
1×
1×
3×
1×
1×
1×
1×
d
c
b
a
e
f
g
h
i
j
2×
a
Installation and operation manual
b
General safety precautions
c
Washers for hanger bracket
d
Screws for duct flanges
e
Metal clamp
f
Sealing pads: Large (drain pipe), medium 1 (gas pipe),
medium 2 (liquid pipe)
g
Drain hose
h
Insulation piece: Small (liquid pipe)
i
Insulation piece: Large (gas pipe)
j
Wire for common power supply
12
Unit installation
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
12.1
Preparing the installation site
WARNING
The appliance using R32 refrigerant shall be stored so as
to prevent mechanical damage and in a well-ventilated
room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance, or an operating
electric heater). The room size shall be as specified in the
General safety precaution.
12.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
▪ Use
suspension bolts
for installation.
▪
Spacing
. Mind the following requirements:
≥300
a
e
b
f
g
d
c
a
Service space
b
Drain pipe
c
Power supply wiring port
d
Transmission wiring port
e
Maintenance drain outlet
f
Gas pipe
g
Liquid pipe
▪
Installation options: