background image

English

4

HEATING

D

 

B: Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote con-
troller is 16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following 

places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels

 

f

 

. Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

OUTDOOR 

UNIT

TEMPERATURE(°C)

OUTDOOR

INDOOR

HEAT 
PUMP 
TYPE

RY-FUV1/Y1

D
B

–9 to 21

D
B

15 to 27

W

B

–10 to 15.5

RY-FUVAL/TAL

D
B

–9 to 21

D
B

15 to 24

W

B

–10 to 15.5

RY-K(U)
V1/Y1

D
B

–9 to 21

D
B

15 to 27

W

B

–10 to 15

RY-KTAL/YAL

D
B

–9 to 21

D
B

15 to 27

W

B

–10 to 15

4. INSTALLATION SITE

• Make sure that a separate power supply cir-

cuit is provided for this air conditioner and 
that all electrical work is carried out by quali-
fied personnel according to local laws and 
regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

 Refer to figure 1 on page [1] 

The illustrations in this operating manual corre-
spond to the remote control format BRC1C type. 
Although the display and shape of the buttons on 
the BRC1B type are slightly different, they may be 
operated in the same manner.

5. NAME AND FUNCTION OF EACH 

SWITCH AND  DISPLAY ON THE 
REMOTE CONTROLLER 

1

ON/OFF BUTTON

Press the button and the system will start. Press 
the button again and the system will stop.

2

OPERATION LAMP (RED)

The lamp lights up during operation.

3

DISPLAY “

” (UNDER CENTRAL-

IZED CONTROL)

When this display shows, the system is 
UNDER CENTRALIZED CONTROL. 

01_EN_3PN02535-7P.fm  Page 4  Friday, December 9, 2005  1:08 PM

Summary of Contents for FD(Y)M03FAV1(C)

Page 1: ...ANUAL MODELS Duct connection type FD Y M03FAV1 C FD Y M03FAVAL FD Y M04FAV1 FD Y M04FAVAL FD Y M05FAV1 FD Y M05FAVAL FDYM06FAV1 FDYM06FAVAL FDYM60FAV1 C FDYM60FAVAL English Espa ol 01_CV_3PN02535 7P f...

Page 2: ...g the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de ai...

Page 3: ...3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 3 1 4 5 6 7 8 13 14 15 16 17 18 19 20 11 9 12 b d e c d a e g f h R Y 100 125 140 R Y 71 C H hr hr 01_CV_3PN02535 7P fm Page 2 Friday December 9 2005 9 1...

Page 4: ...roup control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit In case of...

Page 5: ...old component parts designated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditio...

Page 6: ...ise injury may be caused Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can...

Page 7: ...local laws and regulations Pay attention to running noises too Are the following places selected a A place that can sufficiently withstand the weight of the air conditioner with less running noises a...

Page 8: ...persons for maintenance purposes 16 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1 Operating procedure varies with heat pump type an...

Page 9: ...that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPE...

Page 10: ...on for smooth running Refer to MAINTE NANCE When the display shows TIME TO CLEAN AIR FILTER ask a qualified service person to clean the filters Refer to MAINTENANCE 3 7 OPTIMUM OPERATION 1 3 ONLY A QU...

Page 11: ...HE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared for operation II WHITE MIST COMES OUT OF A UNIT When...

Page 12: ...there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply recovers Check if no fuse has blow...

Page 13: ...3 11 8 10100 56 120 R22 2 6 FDYM05FAVAL RY125FUTAL 220 60 6 7 18 0 12 5 10800 5 6 15 0 15 0 12900 57 115 R22 3 1 FDYM06FAVAL RY140KTAL 220 60 7 0 20 0 14 0 12000 5 9 16 7 17 0 14600 57 114 R22 4 3 JA...

Page 14: ...3PN02535 7P EM01A062A 0602 HT 01_CV_3PN02535 7P fm Page 4 Friday December 9 2005 9 16 PM...

Reviews: