VI.THE LIQUID CRYSTAL OF THE REMOTE CON-

TROLLER SHOW “

• It happens immediately after the main power 

supply switch is turned on.

This shows that the remote controller is in normal 
condition. 
This continues temporary.

I. If one of the following malfunctions occurs, 

take the measures shown below and contact 

your Daikin dealer.

The system must be repaired by a qualified service 
person. 

WARNING

When the air conditioner is in abnormal con-

ditions (smell of something burning, etc), 

unplug the power cord from the outlet, and 

contact your dealer

Continued operation under such circumstances 

may result in a failure, electric shock, and fire.

If a safety device such as a fuse, a breaker or an 
earth leakage breaker frequently actuates;

Measure: 

Do not turn on the main power switch.

If the ON/OFF switch does not properly work;

Measure: 

Turn off the main power switch.

If water leaks from unit.

Measure:

  Stop the operation.

If the display “ 

 ” (INSPECTION), “UNIT No.”, 

and the OPERATION lamp flash and the “MAL-
FUNCTION CODE” appears.

Measure:

 Notify your Daikin dealer and inform 

him/her of the display.

10. TROUBLE SHOOTING

OPERATION lamp

INSPECTION 
display

MALFUNCTION CODE

INDOOR UNIT No. in 
which a malfunction occurs

UNIT   No.

C

L

  H     

II. If the system does not properly operate 

except for the above mentioned case, and 

none of the above mentioned malfunctions is 

evident, investigate the system according to 

the following procedures.

1. If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the system automati-
cally restarts immediately after the power sup-
ply recovers.

Check if no fuse has blown. 
Turn off the power supply. 

Check if the breaker is 
blown.
Turn the power on with 
the breaker switch in 
the off position.
Do not turn the power on with the breaker 
switch in the trip position. 
(Contact your dealer.)

2. If the system stops operating after operating 

the system.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles.
Remove the obstacle and make it well-venti-
lated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

3. The system operates but it does not suffi-

ciently cool or heat.

If the air inlet or outlet of the indoor or the out-
door unit is blocked with obstacles.
Remove the obstacle and make it well-venti-
lated. 

If the air filter is clogged.
Ask a qualified service person to clean the air 
filters (Refer to MAINTENANCE).

If the set temperature is not proper (Refer to 
ADJUSTMENT).

If the FAN SPEED button is set to LOW 
SPEED (Refer to ADJUSTMENT).

If the doors or the windows are open. Shut 
doors or windows to prevent wind from coming 
in.

If direct sunlight enters the room (when cool-
ing).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

If the heat source of the room is excessive 
(when cooling).
Cooling effect decreases if heat gain of the 
room is too large.

Switch

ON

OFF

Trip position

Breaker

01_EN_3PN02535-7P.fm  Page 9  Friday, December 9, 2005  1:08 PM

Summary of Contents for FD(Y)M03FAV1(C)

Page 1: ...ANUAL MODELS Duct connection type FD Y M03FAV1 C FD Y M03FAVAL FD Y M04FAV1 FD Y M04FAVAL FD Y M05FAV1 FD Y M05FAVAL FDYM06FAV1 FDYM06FAVAL FDYM60FAV1 C FDYM60FAVAL English Espa ol 01_CV_3PN02535 7P f...

Page 2: ...g the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de ai...

Page 3: ...3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 3 1 4 5 6 7 8 13 14 15 16 17 18 19 20 11 9 12 b d e c d a e g f h R Y 100 125 140 R Y 71 C H hr hr 01_CV_3PN02535 7P fm Page 2 Friday December 9 2005 9 1...

Page 4: ...roup control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit In case of...

Page 5: ...old component parts designated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditio...

Page 6: ...ise injury may be caused Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can...

Page 7: ...local laws and regulations Pay attention to running noises too Are the following places selected a A place that can sufficiently withstand the weight of the air conditioner with less running noises a...

Page 8: ...persons for maintenance purposes 16 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1 Operating procedure varies with heat pump type an...

Page 9: ...that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPE...

Page 10: ...on for smooth running Refer to MAINTE NANCE When the display shows TIME TO CLEAN AIR FILTER ask a qualified service person to clean the filters Refer to MAINTENANCE 3 7 OPTIMUM OPERATION 1 3 ONLY A QU...

Page 11: ...HE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared for operation II WHITE MIST COMES OUT OF A UNIT When...

Page 12: ...there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply recovers Check if no fuse has blow...

Page 13: ...3 11 8 10100 56 120 R22 2 6 FDYM05FAVAL RY125FUTAL 220 60 6 7 18 0 12 5 10800 5 6 15 0 15 0 12900 57 115 R22 3 1 FDYM06FAVAL RY140KTAL 220 60 7 0 20 0 14 0 12000 5 9 16 7 17 0 14600 57 114 R22 4 3 JA...

Page 14: ...3PN02535 7P EM01A062A 0602 HT 01_CV_3PN02535 7P fm Page 4 Friday December 9 2005 9 16 PM...

Reviews: