Never expose little children, plants or ani-

mals directly to the air flow.

Adverse influence to little children, animals and 

plants may result.

Do not wash the air conditioner with water.

An electric shock or fire may result.

Do not install the air conditioner at any place 

where flammable gas may leak out.

If the gas leaks out and stays around the air con-

ditioner, a fire may break out.

Execute complete drain piping for perfect 

drainage.

Incomplete piping may result in a water leakage.

The appliance is not intended for use by 

young children or infirm persons without 

supervision.
Young children should be supervised to 

ensure that they do not play with the appli-

ance.
Consult with installation contractor for 

cleaning the inside of the air conditioner.

Wrong cleaning may make the plastics parts 

broken or cause failure of water leakage or elec-

tric shock.

Do not touch the air inlet or aluminium fin of 

the air conditioner.

Otherwise, injury may be caused.

Do not place objects in direct proximity of 

the outdoor unit and do not let leaves and 

other debris accumulate around the unit. 

Leaves are a hotbed for small animals which can 

enter the unit. Once in the unit, such animals can 

cause malfunctions, smoke or fire when making 

contact with electrical parts.

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING

3. OPERATION RANGE

OUTDOOR 

UNIT

TEMPERATURE(°C)

OUTDOOR

INDOOR

COOLING 
ONLY 
TYPE

R-FUV1/Y1

D
B

21 to 52

D
B

21 to 35

W

B

14 to 25

R-FUVAL/TAL

D
B

21 to 50

D
B

21 to 35

W

B

14 to 25

R-K(U)V1/Y1

D
B

21 to 46

D
B

21 to 35

W

B

14 to 25

R-K(U)
VAL/TAL

D
B

21 to 46

D
B

21 to 35

W

B

14 to 25

R-KUYAL
R140KTAL/YAL

D
B

21 to 50

D
B

21 to 35

W

B

14 to 25

HEAT 
PUMP 
TYPE

RY-FUV1/Y1

D
B

–5 to 52

D
B

21 to 35

W

B

14 to 25

RY-FUVAL/TAL

D
B

–5 to 50

D
B

21 to 35

W

B

14 to 25

RY-K(U)V1/Y1

D
B

–5 to 46

D
B

21 to 35

W

B

12 to 25

RY-KTAL/YAL

D
B

–5 to 50

D
B

21 to 35

W

B

12 to 25

01_EN_3PN02535-7P.fm  Page 3  Friday, December 9, 2005  1:08 PM

Summary of Contents for FD(Y)M03FAV1(C)

Page 1: ...ANUAL MODELS Duct connection type FD Y M03FAV1 C FD Y M03FAVAL FD Y M04FAV1 FD Y M04FAVAL FD Y M05FAV1 FD Y M05FAVAL FDYM06FAV1 FDYM06FAVAL FDYM60FAV1 C FDYM60FAVAL English Espa ol 01_CV_3PN02535 7P f...

Page 2: ...g the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de ai...

Page 3: ...3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 3 1 4 5 6 7 8 13 14 15 16 17 18 19 20 11 9 12 b d e c d a e g f h R Y 100 125 140 R Y 71 C H hr hr 01_CV_3PN02535 7P fm Page 2 Friday December 9 2005 9 1...

Page 4: ...roup control system One remote controller controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit In case of...

Page 5: ...old component parts designated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditio...

Page 6: ...ise injury may be caused Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can...

Page 7: ...local laws and regulations Pay attention to running noises too Are the following places selected a A place that can sufficiently withstand the weight of the air conditioner with less running noises a...

Page 8: ...persons for maintenance purposes 16 PROGRAMMING TIME BUTTON Use this button for programming START and or STOP time hr hr C Refer to figure 1 on page 1 Operating procedure varies with heat pump type an...

Page 9: ...that you use a circulator a fan to circulate the air inside the room For details consult your dealer For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPE...

Page 10: ...on for smooth running Refer to MAINTE NANCE When the display shows TIME TO CLEAN AIR FILTER ask a qualified service person to clean the filters Refer to MAINTENANCE 3 7 OPTIMUM OPERATION 1 3 ONLY A QU...

Page 11: ...HE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared for operation II WHITE MIST COMES OUT OF A UNIT When...

Page 12: ...there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply recovers Check if no fuse has blow...

Page 13: ...3 11 8 10100 56 120 R22 2 6 FDYM05FAVAL RY125FUTAL 220 60 6 7 18 0 12 5 10800 5 6 15 0 15 0 12900 57 115 R22 3 1 FDYM06FAVAL RY140KTAL 220 60 7 0 20 0 14 0 12000 5 9 16 7 17 0 14600 57 114 R22 4 3 JA...

Page 14: ...3PN02535 7P EM01A062A 0602 HT 01_CV_3PN02535 7P fm Page 4 Friday December 9 2005 9 16 PM...

Reviews: