3. OPERATION RANGE
If the temperature or the humidity is beyond the following
conditions, safety devices may work and the air conditioner may
not operate, or sometimes, water may drop from the indoor unit.
COOLING
For FCA
7
1AV16
INDOOR
OUTDOOR
OUTDOOR
UNIT
TEMPERA-
TEMPERA-
TURE
HUMIDITY
TURE
D
19 to 35
B
D
RZCA
80% or below
B
21 to 52
w
14 to 24
B
HEATING
OUTDOOR
INDOOR
OUTDOOR
UNIT
TEMPERATURE
TEMPERATURE
RZCA
D
10
to
27
B
DB: Dry bulb temperature (
°
C}
WB: Wet bulb temperature (
°
C}
D
B
-10
to
24
w
-10
to
18
B
For setting temperature range of the remote controller,
please refer manual attached with remote.
4. INSTALLATION SITE
Regarding places for installation
• Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
• Do not use the air conditioner in the following places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring resort
d. Where there are considerable voltage fluctuations
such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor such as a
cookery, etc.
g. Where there are machines generating electromagnetic
waves
h. Filled with acid and/or alkaline steam or vapor
• Is a snow protection measure taken?
For details, consult your dealer about snow protection
hoods, etc.
Regarding wiring
• All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
• Make sure that a separate power supply circuit is
provided for this air conditioner and that all electrical
work is carried out by qualified personnel according
to local laws and regulations.
Pay attention to running noises, too
• Are the following places selected?
a. A place that can sufficiently withstand the weight of the
air conditioner with less running noises and vibrations.
b. A place where the hot wind discharged from the air
outlet of the outdoor unit and the running noises do
not cause a nuisance to neighbours.
• Are you sure that there are no obstacles near the air
outlet of the outdoor unit?
Such obstacles may result in declined performance and
increased running noises.
• If
abnormal noises occur in use, stop the operation
of the air conditioner, consult your dealer.
System relocation
57
• Consult your Daikin dealer about remodelling and
relocation.
Regarding drainage of drain pipe
• Is the drain pipe executed to perform complete
drainage?
If proper drainage is not carried out from the outdoor drain
pipes during air-conditioning operation, chances are that
dust and dirt are clogged in the pipe. This may result in a
water leakage from the indoor unit. Under such
circumstances, stop the operation of the air conditioner,
and then consult your dealer or our service station.
5. OPERATION PROCEDURE
• Operation procedure
Read the operation manual attached to the remote
controller.
• Operation procedure varies with heat pump type and
cooling only type. Contact your local dealer to confirm
your system type.
• To protect the unit, turn on the main power supply switch
6 hours before operation.
• Do not shut off the power supply during seasonal use of
the air conditioner.
This is required in order to activate the air conditioner
smoothly.
• If the main power supply switch is turned off during
operation, operation will restart automatically after the
power truns back on again.
Summary of Contents for FCA71AV16
Page 34: ...33 RZCA71AV16...
Page 35: ...34 RZCA71AV16...
Page 36: ...35...
Page 37: ...36...
Page 38: ...37...
Page 39: ...38 RZCA71AV16...
Page 40: ...39 RZCA71AV16...
Page 41: ...40...
Page 42: ...41...
Page 43: ...42 RZCA71AV16 RZCA71AV16 20 g per meter For Piping Length Exceeding 10 m RZCA71AV16...
Page 44: ...43 45...
Page 45: ...44 RZCA71AV16 RZCA71AV16...
Page 46: ...45 RZCA71AV16 RZCA71AV16 Power Supply 50 Hz 230 V...
Page 47: ...46...
Page 50: ...49...
Page 51: ...50 RZCA71AV16...