5 About the units and options
Installation manual
9
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726857-1 – 2023.03
b
b
c
c
a
Special transport pallet
b
Sling
c
Fixing points A1
DANGER
Always use a safety harness when working at height.
WARNING
Make sure that the forklift, or any other lifting device used,
can bear the weight of the unit.
INFORMATION
See
23] for the weight of the unit.
INFORMATION
Cut a hole in the plastic wrapping to gain access to the
lifting eyes when using a lifting device and lifting slings.
2
Standing on a ladder or work-stand, hook the slings (b) onto the
fixing points (c).
b
c
b
c
b
Sling
c
Fixing points A1
3
Lift the unit with a lifting device (e.g. overhead crane).
4
Remove the plastic film from around the unit.
WARNING
Tear apart and throw away plastic packaging bags so that
nobody, especially NOT children, can play with them.
Possible consequence:
suffocation.
5
About the units and options
5.1
System layout
f
e
d
c
j
a
i
l m
b
o p
k
h
n
g
q r
a
Condenser
b
Compressor
c
Battery
d
Generator
e
Fuel lines
f
Fuel line connectors
g
IoT module
h
USB Serial Port
i
Grid electrical plug
j
User interface
k
Electrical box
l
Engine
m
ON/OFF switch
n
Evaporator
o
Radiator
p
Exhaust
q
Fuel pump
r
Fuel pre-filter