4
|
Components
Service manual
57
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04 – 2022.04
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite:
Remove the front grille.
1
Remove 1 screw from the electrical wiring box.
2
Open the electrical wiring box cover by pulling it to the front.
3
Remove the electrical wiring box cover from the 2 rear hooks.
a
1
b
c
c
2
a
Screw
b
Electrical wiring box
c
Rear hook
4
To re-install the cover, first attach the electrical wiring box to the hooks, close
the electrical wiring box, and re-install the screw.
NOTICE
When closing the electrical wiring box cover, make sure that the tightening torque
does NOT exceed 2.0 (±0.2) N•m.
To remove the switch box
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
48].
1
Disconnect the power supply wiring from the power supply terminal X1M.
2
Remove the screw and power supply wiring bracket.
3
Pull the clip and remove the heat exchanger thermistor from its holder.
4
Remove the screw to disconnect the grounding wire from the heat exchanger
draft – 22/04/2022 08:50