background image

4 About the unit

Installation manual

4

FVXM25~50A2V1B

Split system air conditioners

3P477070-2H – 2020.06

4

About the unit

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

Following symbols may occur on the indoor unit:

Symbol

Explanation

Measure the voltage at the terminals of main circuit
capacitors or electrical components before servicing.

4.1

About the wireless LAN

For detailed specifications, installation instructions, setting methods,
FAQ, declaration of conformity and the latest version of this manual,
visit 

http://www.onlinecontroller.daikineurope.com

.

INFORMATION

▪ Daikin  Industries  Czech  Republic  s.r.o.  declares  that

the  radio  equipment  type  inside  of  this  unit  is  in
compliance with Directive 2014/53/EU.

▪ This  unit  is  considered  as  combined  equipment

according to the definition of Directive 2014/53/EU.

4.1.1

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

4.1.2

Basic parameters

What

Value

Frequency range

2400 MHz~2483.5 MHz

Radio protocol

IEEE 802.11b/g/n

Radio frequency channel

13ch

Output power

13 dBm

Effective radiated power

15 dBm (11b) / 14 dBm (11g) /
14 dBm (11n)

Power supply

DC 14 V / 100 mA

4.1.3

Setting the wireless LAN

The customer is responsible for providing:

▪ Smartphone or tablet with minimum supported version of Android

or iOS, specified on 

http://www.onlinecontroller.daikineurope.com

▪ Internet  line  and  communicating  device,  such  as  modem,  router,

etc.

▪ Wireless LAN access point.

▪ Installed free Daikin Residential Controller application.

To install the Daikin Residential Controller
application

1

Open:

▪ Google Play for appliances using Android.
▪ App Store for appliances using iOS.

2

Search for Daikin Residential Controller.

3

Follow the directions on the screen to install.

5

Unit installation

5.1

Preparing the installation site

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

5.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

Spacing.

 Mind the following requirements:

60

(65)

≤27°

(mm)

≥467

≥50

≥50

A

B

(105)

60

A

Front view

B

Side view

▪ Do not install the unit more than 60 mm above the floor.

Wall insulation

. When conditions in the wall exceed 30°C and a

relative  humidity  of  80%,  or  when  fresh  air  is  inducted  into  the
wall,  then  additional  insulation  is  required  (minimum  10  mm
thickness, polyethylene foam).

Wall  or  floor  strength.

  Check  whether  the  wall  or  the  floor  is

strong enough to support the weight of the unit. If there is a risk,
reinforce the wall or the floor before installing the unit.

5.2

Opening the indoor unit

5.2.1

To remove the front panel

1

Slide both sliders in the direction of the arrows until they click.

2

Open the front panel and undo the string.

Summary of Contents for CVXM20A2V1B

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners CVXM20A2V1B FVXM25A2V1B FVXM35A2V1B FVXM50A2V1B...

Page 2: ...ical data 11 11 1 Wiring diagram 12 11 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask...

Page 3: ...ticularly on the high pressure side Do NOT use taped wires stranded conductor wires extension cords or connections from a star system They can cause overheating electrical shock or fire Do NOT install...

Page 4: ...0 mA 4 1 3 Setting the wireless LAN The customer is responsible for providing Smartphone or tablet with minimum supported version of Android or iOS specified on http www onlinecontroller daikineurope...

Page 5: ...trical wiring box cover 1 Open the terminal block 2 Remove 1 screw from the electrical wiring box 3 Unhook the 2 tabs on the electrical wiring box cover and remove it b a c c b a Screw b Wiring box co...

Page 6: ...iping hole location g Left bottom piping hole location h Right bottom piping hole location 6 Temporarily secure the mounting plate on the wall 7 Make sure the mounting plate is level 8 Mark the centre...

Page 7: ...it 44 22 Secure the unit to the extra filler board and to the floor using 6 screws M4 25L field supply 6 23 When the complete installation is finished attach the front panel and the front grille in th...

Page 8: ...extension hose use a polyvinyl adhesive agent for glueing Condensation Take measures against condensation Insulate the complete drain piping in the building To connect the drain piping to the indoor...

Page 9: ...higher than 30 C and the humidity is higher than RH 80 the thickness of the insulation materials should be at least 20 mm to prevent condensation on the surface of the insulation 6 2 Connecting the re...

Page 10: ...Pull the wires to make sure that they are securely attached then retain the wires with the cable clamp 6 Make sure that the wires do not come in contact with the metal parts of the heat exchanger 7 I...

Page 11: ...performed in cooling or heating mode Prerequisite Test run should be performed in accordance with the operation manual of the indoor unit to make sure that all functions and parts are working properl...

Page 12: ...ght emitting diode HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic relay L Live Symbol Me...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P477070 2H 2020 06 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...