background image

Table of Contents

Installation manual

2

FVXM25~50A2V1B

Split system air conditioners

3P477070-2H – 2020.06

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 Specific installer safety instructions

2

3 About the box

3

3.1

Indoor unit .................................................................................

3

3.1.1

To remove the accessories from the indoor unit.........

3

4 About the unit

4

4.1

About the wireless LAN .............................................................

4

4.1.1

Precautions when using the wireless LAN..................

4

4.1.2

Basic parameters ........................................................

4

4.1.3

Setting the wireless LAN.............................................

4

5 Unit installation

4

5.1

Preparing the installation site ....................................................

4

5.1.1

Installation site requirements of the indoor unit ..........

4

5.2

Opening the indoor unit .............................................................

4

5.2.1

To remove the front panel...........................................

4

5.2.2

To remove the front grille ............................................

5

5.2.3

To open the terminal block and remove the electrical
wiring box cover ..........................................................

5

5.3

Mounting the indoor unit............................................................

5

5.3.1

To install the indoor unit..............................................

5

5.3.2

To drill a wall hole .......................................................

7

5.3.3

To remove the slit portions..........................................

7

5.3.4

To provide drainage ....................................................

8

6 Piping installation

9

6.1

Preparing refrigerant piping .......................................................

9

6.1.1

Refrigerant piping requirements..................................

9

6.1.2

Refrigerant piping insulation .......................................

9

6.2

Connecting the refrigerant piping ..............................................

9

6.2.1

To connect the refrigerant piping to the indoor unit ....

9

7 Electrical installation

9

7.1

Specifications of standard wiring components ..........................

10

7.2

To connect the electrical wiring to the indoor unit .....................

10

7.3

To connect optional accessories (wired user interface, central
user interface, wireless adapter, etc.) .......................................

10

8 Finishing the indoor unit installation

10

8.1

To finish the indoor unit installation ...........................................

10

8.2

To close the indoor unit .............................................................

11

8.2.1

To close the electrical wiring box and close the
terminal block.............................................................. 11

8.2.2

To re-install the front grille .......................................... 11

8.2.3

To re-install the front panel ......................................... 11

9 Commissioning

11

9.1

To perform a test run .................................................................

11

9.1.1

To perform a test run using the user interface ............ 11

10 Disposal

11

11 Technical data

11

11.1

Wiring diagram ..........................................................................

12

11.1.1

Unified wiring diagram legend..................................... 12

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

WARNING

Make  sure  installation,  servicing,  maintenance,  repair  and
applied materials follow the instructions from Daikin and, in
addition,  comply  with  applicable  legislation  and  are
performed  by  qualified  persons  only.  In  Europe  and  areas
where  IEC  standards  apply,  EN/IEC  60335-2-40  is  the
applicable standard.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

Specific installer safety
instructions

Always observe the following safety instructions and regulations.

Unit installation (see 

"5 Unit installation" 

[

4

 4])

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

Summary of Contents for CVXM20A2V1B

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners CVXM20A2V1B FVXM25A2V1B FVXM35A2V1B FVXM50A2V1B...

Page 2: ...ical data 11 11 1 Wiring diagram 12 11 1 1 Unified wiring diagram legend 12 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask...

Page 3: ...ticularly on the high pressure side Do NOT use taped wires stranded conductor wires extension cords or connections from a star system They can cause overheating electrical shock or fire Do NOT install...

Page 4: ...0 mA 4 1 3 Setting the wireless LAN The customer is responsible for providing Smartphone or tablet with minimum supported version of Android or iOS specified on http www onlinecontroller daikineurope...

Page 5: ...trical wiring box cover 1 Open the terminal block 2 Remove 1 screw from the electrical wiring box 3 Unhook the 2 tabs on the electrical wiring box cover and remove it b a c c b a Screw b Wiring box co...

Page 6: ...iping hole location g Left bottom piping hole location h Right bottom piping hole location 6 Temporarily secure the mounting plate on the wall 7 Make sure the mounting plate is level 8 Mark the centre...

Page 7: ...it 44 22 Secure the unit to the extra filler board and to the floor using 6 screws M4 25L field supply 6 23 When the complete installation is finished attach the front panel and the front grille in th...

Page 8: ...extension hose use a polyvinyl adhesive agent for glueing Condensation Take measures against condensation Insulate the complete drain piping in the building To connect the drain piping to the indoor...

Page 9: ...higher than 30 C and the humidity is higher than RH 80 the thickness of the insulation materials should be at least 20 mm to prevent condensation on the surface of the insulation 6 2 Connecting the re...

Page 10: ...Pull the wires to make sure that they are securely attached then retain the wires with the cable clamp 6 Make sure that the wires do not come in contact with the metal parts of the heat exchanger 7 I...

Page 11: ...performed in cooling or heating mode Prerequisite Test run should be performed in accordance with the operation manual of the indoor unit to make sure that all functions and parts are working properl...

Page 12: ...ght emitting diode HAP Light emitting diode service monitor green HIGH VOLTAGE High voltage IES Intelligent eye sensor IPM Intelligent power module K R KCR KFR KHuR K M Magnetic relay L Live Symbol Me...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P477070 2H 2020 06 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...