![background image](http://html.mh-extra.com/html/daikin/arxs20g2v1b/arxs20g2v1b_service-manual_501340271.webp)
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
SiENBE04-808_A
259
Removal Procedure
4.8
Removal of Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
2
Disconnect the lead
wires of the
compressor.
3
Unfasten the hooks with
a flat screwdriver to
remove the overload
protector.
(R8195)
Terminal cover
(R8196)
Red (U)
Yellow (V)
Blue
(W)
U
W
V
(R8197)
U
W
V
(R8198)
U
W
V
SiENBE04-808_A.pdf 271