SiENBE04-808_A
Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
Removal Procedure
220
8
Release the discharge
pipe thermistor.
Be careful not to lose the clip
for the thermistor.
9
Lift and remove the
electrical box.
Step
Procedure
Points
Discharge pipe thermistor
(R11849)
(R12279)
Clip
(R11852)
Electrical Box
SiENBE04-808_A.pdf 232