![background image](http://html.mh-extra.com/html/daikin/arxs20g2v1b/arxs20g2v1b_service-manual_501340178.webp)
SiENBE04-808_A
Indoor Unit
Removal Procedure
166
5
Disconnect the
connector for swing
motors [S41].
6
Release the harness for
swing motors from the
hook.
7
Pull out the indoor heat
exchanger thermistor.
Be careful not to lose the
clip of the thermistor.
8
Remove the screw and
detach the earth wire.
Step
Procedure
Points
(R7935)
[S41]
(R7936)
(R7937)
Indoor heat exchanger thermistor
Clip
(R11268)
(R7938)
Earth wire
SiENBE04-808_A.pdf 178