![background image](http://html.mh-extra.com/html/daikin/arxs20g2v1b/arxs20g2v1b_service-manual_501340234.webp)
SiENBE04-808_A
Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
Removal Procedure
222
4
Pull out the forced
operation button PCB.
Disconnect the
connector [S110] to
remove the forced
operation button PCB.
Be careful of a sharp
protrusion at the back of the
forced operation button
PCB.
5
Disconnect the relay
connector.
6
Cut the clamp.
Step
Procedure
Points
(R11856)
Forced operation button PCB
(R11857)
(R11858)
SiENBE04-808_A.pdf 234