Main Functions
SiBE04-809
16
Function and Control
1.2
Power-Airflow Flap, Wide-Angle Louvres and Auto-
Swing
Power-airflow
Flap
The large flap sends a large volume of air downwards to the floor. The flap provides an optimum
control area in cooling, heating and dry mode.
Heating Mode
During heating mode, the large flap enables direct warm air straight downwards. The flap
presses the warm air above the floor to reach the entire room.
Cooling Mode
During cooling mode, the flap retracts into the indoor unit. Then, cool air can be blown far and
pervaded all over the room.
Wide-Angle
Louvres
The louvres, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing
The following table explains the auto-swing process for heating, cooling, dry and fan :
Outline of
3-D
Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room. This function is effective for starting the air conditioner.
Detail of the
Action
When the horizontal swing and vertical swing are both set to auto mode, the airflow become 3-D
airflow and the horizontal swing and vertical swing motions are alternated. The order of swing
motion is such that it turns counterclockwise, starting from the right upper point as viewed to the
front side of the indoor unit.
COMFORT
AIRFLOW Mode
The vertical swing flap is controlled not to blow the air directly on the person in the room.
The airflow rate is set to AUTOMATIC.
The airflow rate has the upper limit (M tap) in heating mode.
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Heating
Cooling, Dry
Fan
(R3293)
30˚
75˚
(R3294)
10˚
40˚
(R3295)
5˚
80˚
(R3296)
35˚
35˚
(R1024)
Heating
Cooling, Dry
(R3297)
80˚
(R3298)
5˚
Summary of Contents for ARXG25E3V1B
Page 1: ...SiBE04 809 Applied Models Inverter Pair Heat Pump Inverter Pair Wall Mounted Type E Series ...
Page 11: ...Introduction SiBE04 809 x ...
Page 12: ...SiBE04 809 List of Functions 1 Part 1 List of Functions 1 List of Functions 2 ...
Page 14: ...SiBE04 809 Specifications 3 Part 2 Specifications 1 Specifications 4 ...