![Daikin Altherma 3 R F EHVZ04S18E 6V Series Installer'S Reference Manual Download Page 96](http://html.mh-extra.com/html/daikin/altherma-3-r-f-ehvz04s18e-6v-series/altherma-3-r-f-ehvz04s18e-6v-series_installers-reference-manual_501222096.webp)
9
|
Electrical installation
Installer reference guide
96
ERGA04~08EAV3(A) + 08S18+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
Item
Description
Heat pump convector
There are different controllers and setups
possible for the heat pump convectors.
Depending on the setup, you also need to
implement a relay (field supply, see
addendum book for optional equipment).
For more information, see:
▪
Installation manual of the heat pump
convectors
▪
Installation manual of the heat pump
convector options
▪
Addendum book for optional equipment
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪
[2.9]
Control
▪
[2.A]
Thermostat type
For the additional zone:
▪
[3.A]
Thermostat type
▪
[3.9] (read-only)
Control
Remote outdoor sensor
See:
▪
Installation manual of the remote outdoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[9.B.1]=1 (
External sensor
=
Outdoor
)
[9.B.2]
Ext. amb. sensor offset
[9.B.3]
Averaging time
Remote indoor sensor
See:
▪
Installation manual of the remote indoor
sensor
▪
Addendum book for optional equipment
Wires: 2×0.75 mm²
[9.B.1]=2 (
External sensor
=
Room
)
[1.7]
Room sensor offset