![Daikin Altherma 3 R F EHVZ04S18E 6V Series Installer'S Reference Manual Download Page 201](http://html.mh-extra.com/html/daikin/altherma-3-r-f-ehvz04s18e-6v-series/altherma-3-r-f-ehvz04s18e-6v-series_installers-reference-manual_501222201.webp)
11
|
Commissioning
Installer reference guide
201
ERGA04~08EAV3(A) + 08S18+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
NOTICE
To perform an underfloor heating screed dryout, room frost protection needs to be
disabled ([2‑06]=0). By default, it is enabled ([2‑06]=1). However, due to the
"installer-on-site" mode (see "Commissioning"), room frost protection will be
automatically disabled for 36 hours after the first power-on.
If the screed dryout still needs to be performed after the first 36 hours of power-on,
manually disable room frost protection by setting [2‑06] to "0", and KEEP it disabled
until the screed dryout has finished. Ignoring this notice will result in cracking of the
screed.
NOTICE
For the underfloor heating screed dryout to be able to start, make sure the following
settings are met:
▪
[4‑00]=1
▪
[C‑02]=0
▪
[D‑01]=0
▪
[4‑08]=0
▪
[4‑01]≠1
Steps
Conditions:
An underfloor heating screed dryout schedule has been programmed.
See
" To program an underfloor heating screed dryout schedule"
200].
Conditions:
Make sure all operation is disabled. Go to [C]:
Operation
and turn off
Room
,
Space heating/cooling
and
Tank
operation.
1
Set the user permission level to
Installer
. See
117].
—
2
Go to [A.4]:
Commissioning
>
UFH screed dryout
.
3
Select
Start UFH screed dryout
.
4
Select
OK
to confirm.
Result:
The underfloor heating screed dryout starts. It stops
automatically when done.
5
To stop the underfloor heating screed dryout manually:
—
1
Open the menu and go to
Stop UFH screed dryout
.
2
Select
OK
to confirm.
To read out the status of an underfloor heating screed dryout
Conditions:
You are performing an underfloor heating screed dryout.
1
Press the back button.
Result:
A graph is displayed, highlighting the current step of the
screed dryout schedule, the total remaining time, and the
current desired leaving water temperature.
2
Press the left dial to open the menu structure and to:
1
View the status of sensors and actuators.
—
2
Adjust the current program
—
Summary of Contents for Altherma 3 R F EHVZ04S18E 6V Series
Page 253: ......
Page 254: ......
Page 255: ......
Page 256: ...4P629093 1 2020 08 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...