![Daikin Altherma 3 R F EHVZ04S18E 6V Series Installer'S Reference Manual Download Page 251](http://html.mh-extra.com/html/daikin/altherma-3-r-f-ehvz04s18e-6v-series/altherma-3-r-f-ehvz04s18e-6v-series_installers-reference-manual_501222251.webp)
9/10
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[9-0E]
R/W
0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
9.I
[C-00]
R/O
1: Heat pump priority
9.I
[C-01]
0
9.I
[C-02]
R/W
0: No
1: Bivalent
9.I
[C-03]
R/W
-25~25°C, step: 1°C
0°C
9.I
[C-04]
R/W
2~10°C, step 1°C
3°C
9.I
[C-05]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-06]
R/W
0: -
1: 1 contact
2: 2 contacts
9.I
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.I
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I
[C-09]
R/W
0: Normally open
1: Normally closed
9.I
[C-0A]
0
9.I
[C-0B]
0
9.I
[C-0C]
0
9.I
[C-0D]
0
9.I
[C-0E]
0
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart grid
9.I
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: Forced off
1: As normal
9.I
[D-07]
R/O
0: No
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
0
9.I
[E-02]
R/O
1: Heating only
9.I
[E-03]
R/O
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/O
0: No
1: Yes
9.I
[E-06]
R/O
0: No
1: Yes
9.I
[E-07]
R/O
1: Integrated
9.I
[E-08]
R/W
0: Disabled
1: Enabled
9.I
[E-09]
1
9.I
[E-0A]
0
9.I
[E-0B]
R/O
1: Yes
9.I
[E-0C]
0
9.I
[E-0D]
0
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
20
9.I
[F-02]
R/W
3~10°C, step: 1°C
3°C
Pump speed limitation main zone
Domestic heating water priority.
What is the thermo request contact type for the main zone?
Which heaters are permitted if prefer. kWh rate PS is cut?
--
--
--
--
Bivalent hysteresis temperature.
--
Is an external backup heat source connected?
Bivalent activation temperature.
Contact type of preferential kWh rate PS installation?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
--
Leaving water temperature compensation around 0°C.
--
Which type of DHW pump is installed?
Is a demand PCB connected?
Is the power saving function available on the outdoor unit?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
--
--
--
--
What is the indoor unit software type?
What is the number of backup heater steps?
Which type of compressor is installed?
Pump operation allowed outside range.
Is glycol present in the system?
--
--
Which type of unit is installed?
Power saving function for outdoor unit.
Is a bi-zone kit installed?
--
Bottom plate heater ON temperature.
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
--
--
Is an external kWh meter used for power measurement?
(*1) *3V_
(*2) *6V_
(*3) *9W
(#) Setting is not applicable for this unit.
4P629095-1 - 2020.09
Summary of Contents for Altherma 3 R F EHVZ04S18E 6V Series
Page 253: ......
Page 254: ......
Page 255: ......
Page 256: ...4P629093 1 2020 08 Copyright 2020 Daikin Verantwortung für Energie und Umwelt ...