![Daikin Altherma 3 R F EHVZ04S18E 6V Series Installer'S Reference Manual Download Page 95](http://html.mh-extra.com/html/daikin/altherma-3-r-f-ehvz04s18e-6v-series/altherma-3-r-f-ehvz04s18e-6v-series_installers-reference-manual_501222095.webp)
9
|
Electrical installation
Installer reference guide
95
ERGA04~08EAV3(A) + 08S18+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
9.3 Connections to the indoor unit
Item
Description
Power supply (main)
See
"9.3.1 To connect the main power
98].
Power supply (backup
heater)
See
"9.3.2 To connect the backup heater power
Shut-off valve
See
"9.3.3 To connect the shut-off valve"
102].
Electricity meters
See
"9.3.4 To connect the electricity meters"
103].
Domestic hot water pump
See
"9.3.5 To connect the domestic hot water
Alarm output
See
"9.3.6 To connect the alarm output"
Space heating operation
control
See To connect the space heating ON/OFF output.
Changeover to external
heat source control
See
"9.3.7 To connect the changeover to external
Power consumption digital
inputs
See
"9.3.8 To connect the power consumption
107].
Safety thermostat
See
"9.3.9 To connect the safety thermostat
Smart Grid
See
"9.3.10 To connect a Smart Grid"
110].
Room thermostat (wired or
wireless)
In case of wireless room thermostat
, see:
▪
Installation manual of the wireless room
thermostat
▪
Addendum book for optional equipment
In case of wired room thermostat without
multi-zoning base unit
, see:
▪
Installation manual of the wired room
thermostat
▪
Addendum book for optional equipment
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪
[2.9]
Control
▪
[2.A]
Thermostat type
For the additional zone:
▪
[3.A]
Thermostat type
▪
[3.9] (read-only)