16
|
Technical data
Installer reference guide
237
ERGA04~08EAV3(A) + 08S18+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
Electrical connection diagram
For more details, please check the unit wiring.
2x0.75
2x0.75
2x0.75
1
1
2
2
2
3
3
(F1B)
X1M: 1-2-3
X2M: 5-6
X5M: 9-10
X5M: 13-14
X5M: 13
X5M: 14
X10M: 1-2
2x0.75
X10M: 3-4
A8P: X801M: 1-5
A8P: X801M: 2-5
A8P: X801M: 3-5
A8P: X801M: 4-5
A4P: Y1-YC
X2M: 7-9
A4P: X1-X2
X5M: 11-12
X2M: 1-2
X5M: 7-8
X5M: 5-6
X5M: 3-4
A4P: Y2-YC
X2M: 7-9
4
5
5
5
6
6
4
4
2x0.75
2x0.75
A15P: X1M: H-C-com
X2M: L-N
A2P: X1M: 1-3
A3P: X11M: 3-4-5-6
R2T
230 V
230 V
230 V
230 V
A2P: X1M: C-com-H
X1M: 1-2-3
4D130331A
A11P: X5: 4-5
A11P: X9: 1-2-3
- In case of signal cable: keep minimum distance to power cables >5 cm
Notes:
Field supply
Optional part
Field supply
Only for KRCS01-1 or EKRSCA1
2-way valve
signal
2 core
signal
2 core
signal
2 core
signal
2 core
Power limitation
demand input 4
Power limitation
demand input 3
Power limitation
demand input 2
Power limitation
demand input 1
Field supply
Only for *KRP1AHTA
Only for *KRP1HB*
Field supply
Indoor unit
Cooling/heating
On/OFF output
Electricity meter pulse input 2
Smart Grid pulse meter
Smart Grid contact K2A
Smart Grid contact S11S
Electricity meter pulse input 1
external thermistor (indoor or outdoor)
Circulation pump for DHW
M2S for cooling mode
Ext. heat source (e.g. boiler)
alarm indication
2 core
2 core
signal
2 core
signal
signal
2 core
2 core
2 core
signal
2 core
2 core
External sensor
(floor or ambient)
Only for *KRTETS
signal
2 core
(3m included)
A13P: P1-P2 LAN adapter
A14P: P1-P2 user interface
Only for
(heat pump convector)
Only for remote user interface
Only for *KRTR
(wireless room thermostat)
Only for *KRTW
(wired room thermostat)
4 core
2 core
communication
2 core
communication
2 core
4 core
Optional part
External room thermostat / Heat pump convector
(main and/or additional zone)
main: X2M: 30-35
add: X2M: 30-35a
main & add: X2M: 3-4
main: X2M: 30-31-34-35
add: X2M: 30-31-34a-35a
main: X2M: 30-34-35
add: X2M: 30-34a-35a
Cooling/heating
On/OFF output
NO valve: X2M: 21-28
NC valve: X2M: 21-29
Changeover to
ext. heat source output
Alarm output
X6M: L1-L2-L3 + earth
or L-N + earth
or L1-L2-L3-N + earth
5 or 4 or 3
core
backup heater power supply (3/6/9 kW): 400 V or 230 V + earth
3 core
3 core
3 core
2 core
2 core
2 core
2 core
X1M: L-N-earth
Normal kWh rate power supply for indoor unit: 230 V
Smart Grid contact S10S
Only for LV Smart Grid
Smart Grid contact K1A
Only for LV Smart Grid
Safety thermostat Q4L
Smart Grid relais K1A
2 core
Smart Grid relais K2A
Preferential kWh rate power supply contact
unit preferential kWh rate power supply:
230 V + earth
Only for preferential kWh rate power supply installation
unit power supply: 230 V + earth
Only for normal power supply installation
Outdoor unit
Standard part
Power supply
signal
signal
signal
Only for LV Smart Grid
Only for LV Smart Grid
communication
Optional part
5 core
A20P: J2
(WLAN adapter module)
2x0.75
X5M: 13-14
2 core
Safety thermostat Q4L