8/11
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Installer setting at variance with
default value
Field settings table
9.I
[1-07]
R/W
25~43°C, step: 1°C
35°C(*3)
9.I
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C(*3)
9.I
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0
18°C(*3)
[2-0C]=1
7°C(*3)
[2-0C]=2
18°C(*3)
9.I
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
9.I
[1-0B]
R/W
3~10°C, step: 1°C
5°C
9.I
[1-0C]
R/W
3~10°C, step: 1°C
10°C
9.I
[1-0D]
R/W
3~10°C, step: 1°C
5°C(*3)
9.I
[1-0E]
R/W
3~10°C, step: 1°C
5°C(*3)
9.I
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
9.I
[2-01]
R/W
0: No
1: Yes
9.I
[2-02]
R/W
0~23 hour, step: 1 hour
1
9.I
[2-03]
R/W
60°C
9.I
[2-04]
R/W
40~60 min, step: 5 min
40 min
9.I
[2-05]
R/W
4~16°C, step: 1°C
8°C(*3)
9.I
[2-06]
R/W
0: Disabled
1: Enabled
9.I
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
9.I
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
9.I
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
9.I
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I
[2-0E]
R/W
0~50 A, step: 1 A
50 A
9.I
[3-00]
R/W
0: No
1: Yes
9.I
[3-01]
0
9.I
[3-02]
1
9.I
[3-03]
4
9.I
[3-04]
2
9.I
[3-05]
1
9.I
[3-06]
R/W
18~30°C, step: 0,5°C
30°C
9.I
[3-07]
R/W
12~18°C, step: 0,5°C
12°C
9.I
[3-08]
R/W
25~35°C, step: 0,5°C
35°C(*3)
9.I
[3-09]
R/W
15~25°C, step: 0,5°C
15°C(*3)
9.I
[4-00]
R/W
0: Disabled
1: Enabled
2: Only DHW
9.I
[4-01]
R/W
0: None
1: BSH
2: BUH
9.I
[4-02]
R/W
14~35°C, step: 1°C
35°C
9.I
[4-03]
R/W
0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Legionella only
9.I
[4-04]
R/O
0: Intermittent
9.I
[4-05]
0
9.I
[4-06]
R/W
0: Manual
1: Automatic
2: Auto red SH/ DHW ON
3: Auto red SH/ DHW OFF
4: Auto normal SH/ DHW OFF
9.I
[4-07]
6
9.I
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
9.I
[4-09]
R/W
0: Current
1: Power
9.I
[4-0A]
R/W
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.I
[4-0B]
R/W
1~10°C, step: 0,5°C
1°C(*3)
--
What is the desired delta T in heating for the additional zone?
Water pipe freeze prevention
--
--
--
What is the maximum desired room temperature in heating?
Backup heater configuration
Should the disinfection function be executed?
When should the disinfection function start?
Which electric heater has priority?
Which power limitation mode is required on the system?
Which power limitation type is required?
--
Emergency
Operation permission of the booster heater.
Adjust the offset on the measured room temperature
Adjust the offset on the measured room temperature
Below which outdoor temperature is heating allowed?
When should the disinfection function be executed?
What is the averaging time for the outdoor temp?
What is the mimimum desired room temperature in heating?
What is the BUH operation mode?
Is auto restart of the unit allowed?
--
What is the disinfection target temperature?
What emitter type is connected to the main LWT zone?
What emitter type is connected to the additional LWT zone?
How long must the tank temperature be maintained?
What is the required offset on the measured outdoor temp.?
What is the maximum allowed current over the heatpump ?
Room antifrost temperature
Room frost protection
What is the maximum desired room temperature in cooling?
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
What is the minimum desired room temperature in cooling?
High ambient temp. for LWT main zone cooling WD curve.
Automatic cooling/heating changeover hysteresis.
--
What is the desired delta T in cooling for the main zone?
What is the desired delta T in cooling for the additional zone?
What is the desired delta T in heating for the main zone?
4P586462-1 - 2019.07
(#) Only applicable in Swedish language.
(*1) *6V_
(*2) *9W_
(*3) + EKHVCONV2
Summary of Contents for Altherma 3 H HT EPRA18DAW1
Page 250: ......
Page 251: ......