Configuration
Installer reference guide
146
EPRA14~W1 + ET9W
Daikin Altherma 3 H HT F
4P587503-1A – 2020.01
#
Code
Description
[3.B.1]
[1-0C]
Delta T heating
: A minimum temperature
difference is required for the good operation of
heat emitters in heating mode.
▪
If [2-0D] = 2, this is fixed to 10°C
▪
Else: 3°C~10°C
[3.B.2]
[1-0E]
Delta T cooling
: A minimum temperature
difference is required for the good operation of
heat emitters in cooling mode.
▪
3°C~10°C
9.5.5 Space heating/cooling
Overview
The following items are listed in the submenu:
4
Space heating/cooling
Tank
Additional zone
Main zone
User settings
[4]
Space heating/cooling
[4.1]
Operation mode
[4.2]
Operation mode schedule
[4.3]
Operation range
[4.4]
Number of zones
[4.5]
Pump operation mode
[4.6]
Unit type
[4.7]
Pump limitation
[4.8]
Pump limitation
[4.9]
Pump outside range
[4.A]
Increase around 0°C
[4.B]
Overshoot
[4.C]
Antifrost
To set the space operation mode
1
Go to [4.1]:
Space heating/cooling
>
Operation mode
2
Select one of the following options:
▪
Heating
: Only heating mode
▪
Cooling
: Only cooling mode
▪
Automatic
: The operation mode changes automatically
based on the outdoor temperature. Restricted according to
the operation mode schedule.
Automatic heating/cooling changeover is only applicable when EKHVCONV2 is
installed.
When
Automatic
is selected, the unit switches its operation mode, based on the
Operation mode schedule
[4.2]. In this schedule, the end user indicates which
operation is allowed for each month.
To restrict automatic changeover according to a schedule
Conditions:
You set the space operation mode to
Automatic
.
Summary of Contents for Altherma 3 H HT EPRA18DAW1