VI. Configuration of the system
Before power on, please confirm if the protocol, the Baud rate of the
controlling system and the address code of the IR High-speed dome camera
is right (the factory default is: Pelco_D for protocol, 4800bps for baudrate,
001 for address code). You must make sure that the configuration of them
must be identical to that of the controlling device. The corresponding
switches for configuration is shown in the following figure:
6.1 Configuration of Communication Protocol
The DIP-1 and DIP-2 of the 4-button switch on the PCB board is for
communication protocol configuration. Please refer to the following table:
NO.
2 1
PROTOCOL
1
0 0
PELCO_D
2
0 1
PELCO_P
3
1 0
NEW
4
1 1
PELCO_D1
If the controlling device could only support the preset position numbers below
128, please use PELCO_D1 controlling protocol.