- 61 -
5. The unit has 4 channels alarm input, 1 channel alarm output. Alarm
interaction is realized. When external alarm signal is transmitted to the IR
High Speed Dome Camera, the IR High Speed Dome Camera will turn to the
alarm spot to shoot, and directly show on the screen what happens at the
alarm spot. At the same time, it will output alarm signal at the alarm output
port.
6. Press [IRIS+] button to save and return.
7. Press
[IRIS
-
]
button to exit the menu.
Attention:
A. Alarm input must be ON/OFF input signal, any other types of input
signal(such as power voltage etc) is possible to damage the unit. When
there are alarm signals from multi channels, the unit will respond to them
one by one, the interval is 2 seconds.
B. Once there is alarm signal coming in, the unit will not respond to ―Scan‖,
―Tour‖ etc functions. Manual operation is needed to restore ―Scan‖, ―Tour‖
etc functions.
C. No matter the alarm function is activated or idled, alarm output always
responds. For example, if the alarm function of the unit is not open, when the
unit distinguishes alarm signal, the unit will not be adjusted to corresponding
preset position, but the alarm output still responds.
7.8 Configuration of Privacy Mask function
The process of configuring Privacy Mask Function for the inside SONY
camera module is as below: