background image

System Operation    14 

Parameter  Description 

Card 

You  can  register  five  cards  for  each  user.  On  the  card  registration  interface, 

enter your card number or swipe your card, and then the card information will be 

read by the access controller. 

You  can  enable  the  Duress  Card  function  on  the  card  registration  interface. 

Alarms will be triggered if a duress card is used to unlock the door. 

 

If the access controller is without card reading module, you need to connect the 

device to peripheral card readers.

 

Password 

The door unlocking password. The maximum length of the password is 8 

characters. 

 

If the access controller is without touch screen, you need to connect the access 

controller to a peripheral card reader. There are buttons on the card reader. 

Level 

You can select a user level for new users. There are two options. 

 

User: Users only have door unlock authority. 

 

Admin: Administrators can not only unlock the door but also have 

parameter configuration authority. 

 

In case that you forget the administrator password, you had better create more 

than one administrator. 

Period 

You can set a period in which the user can unlock the door. For detailed period 

settings, see the user manual. 

Holiday 

Plan 

You can set a holiday plan in which the user can unlock the door. For detailed 

holiday plan settings, see the configuration manual. 

Valid Date 

You can set a period during which the unlocking information of the user is valid. 

User Level 

There are six levels: 

 

General: General users can unlock the door normally. 

 

Blacklist: When users in the blacklist unlock the door, service personnel will 

get a prompt. 

 

Guest:  Guests  are  allowed  to  unlock  the  door  certain  times  in  certain 

periods.  Once  they  exceed  the  maximum  times  and  periods,  they  cannot 

unlock the door again. 

 

Patrol: Patrolling users can get their attendance tracked, but they have no 

unlock authority. 

 

VIP: When VIP unlocks the door, service personnel will get a prompt. 

 

Special:  When  special  people  unlock  the  door,  there  will  be  a  delay  of  5 

seconds before the door is closed. 

Use Time 

When the user level is 

Guest

, you can set the maximum times that the guest 

can unlock the door. 

  After you have configured all the parameters, tap 

to save the configuration. 

Step 3

A new user is created. 

 

For access controllers without touch screen, you need to create users through 

management platforms. See details in the user manual.

Summary of Contents for DHI-ASI7213X-T

Page 1: ...Face Recognition Access Controller Quick Start Guide V1 0 0...

Page 2: ...he paper manual CD ROM QR code or our official website If there is inconsistency between paper manual and the electronic version the electronic version shall prevail All the designs and software are s...

Page 3: ...the ventilation of the access controller Operate the access controller within the rated range of power input and output Do not dissemble the access controller Transport use and store the access contr...

Page 4: ...s 1 2 Installation 6 Installation Notes 6 2 1 Cable Connections 7 2 2 Installation 8 2 3 3 System Operation 12 Initialization 12 3 1 Adding New Users 12 3 2 4 Web Operation 15 Notes of Face Recording...

Page 5: ...1 6 The 7 inch access controller has two models model A and model B See Figure 1 1 to Figure 1 4 7 Inch Access Controller Dimensions and components of model A 1 mm inch Figure 1 1 Table 1 1 Component...

Page 6: ...inch Figure 1 2 Table 1 2 Component description 2 No Name No Name 1 USB port 6 IR light 2 MIC 7 Dual camera 3 White fill light 8 Phototransistor 4 Display 9 Cable entry 5 Card swiping area 10 Fingerp...

Page 7: ...a 6 Display 3 White fill light 7 Card swiping area 4 IR light Dimensions and components of model B 2 mm inch Figure 1 4 Table 1 4 Component description 4 No Name No Name 1 MIC 5 Phototransistor 2 Dual...

Page 8: ...ponents 4 Dimensions and components 1 mm inch Figure 1 5 Table 1 5 Component description 1 No Name No Name 1 IR light 6 Phototransistor 2 MIC 7 Dual camera 3 White fill light 8 Cable entry 4 Display 5...

Page 9: ...imensions and components 2 mm inch Figure 1 6 Table 1 6 Component description 2 No Name No Name 1 IR light 6 Phototransistor 2 MIC 7 Dual camera 3 White fill light 8 Cable entry 4 Display 9 Fingerprin...

Page 10: ...ation should be no less than 100Lux It is recommended that the device is installed indoors at least 3 meters away from windows and doors and 2 meters away from lights Avoid back light and direct sunli...

Page 11: ...security module is enabled in Function Security Module If the security module is enabled you need to purchase access control security module separately The security module needs separate power supply...

Page 12: ...3 Ethernet port 4 Ethernet port only supported by 7 inch model B access controllers 5 USB port only supported by 7 inch model B access controllers Installation 2 3 Installation method of model A and...

Page 13: ...Installation 9 Installation height Figure 2 5 Installation diagram 1 Figure 2 6...

Page 14: ...in the bracket Fix the bracket on the wall by installing the expansion screws into the six bracket Step 2 installation holes Connect cables for access controller Step 3 See 2 2 Cable Connections Hang...

Page 15: ...Installation 11 Applying silicon sealant Figure 2 8...

Page 16: ...onsist of 8 to 32 non blank characters and contain at least two types of characters among upper case lower case number and special character excluding For access controller without touch screen initia...

Page 17: ...ecorded and one fingerprint needs to be verified three times You can enable the Duress FP function under each fingerprint and only one of the three fingerprints can be the duress fingerprint Alarms wi...

Page 18: ...set a period in which the user can unlock the door For detailed period settings see the user manual Holiday Plan You can set a holiday plan in which the user can unlock the door For detailed holiday p...

Page 19: ...p 1 controller in the address bar and then press Enter Make sure that the computer used to log in to the web is in the same LAN with the device 7 inch model B access controllers of have dual NICs The...

Page 20: ...ep your face clean Keep the device at least two meters away from light source and at least three meters away from windows or doors otherwise backlight direct sunlight might influence face recognition...

Page 21: ...might be influenced Appendix figure 1 2 Appropriate face position Requirements of Faces Make sure that the face is clean and forehead is not covered by hair Do not wear glasses hats heavy beards or ot...

Page 22: ...n importing face images through the management platform make sure that image resolution is within the range 150 300 600 1200 image pixels are more than 500 500 image size is less than 75KB and image n...

Page 23: ...print is centered on the recording area Do not put the fingerprint sensor at places with intense light high temperature and high humidity If your fingerprints are worn or are unclear try other unlock...

Page 24: ...Fingerprint Record Instruction 20 Appendix figure 2 2 Correct finger pressing Incorrect method Appendix figure 2 3 Wrong finger pressing...

Page 25: ...ed to enable the auto check for updates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client softwar...

Page 26: ...llowing services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMTP Choose TLS to access mailbox server FTP Choose SFTP and set up strong passwords AP hotspot...

Page 27: ...s If there are no communication requirements between two sub networks it is suggested to use VLAN network GAP and other technologies to partition the network so as to achieve the network isolation eff...

Reviews: