This chapter describes the contents covering proper handling of the access controller, hazard 

prevention, and prevention of property damage. Read these contents carefully before using the 

access controller, comply with them when using, and keep it well for future reference. 

Operation Requirement 

 

Do not place or install the access controller in a place exposed to sunlight or near the heat 

source. 

 

Keep the access controller away from dampness, dust or soot. 

 

Keep  the  access  controller  installed  horizontally  on  the  stable  place  to  prevent  it  from 

falling. 

 

Do not drop or splash liquid onto the access controller, and make sure there is no object 

filled  with  liquid  on  the  access  controller  to  prevent  liquid  from  flowing  into  the  access 

controller. 

 

Install the access controller in a well-ventilated place, and do not block the ventilation of 

the access controller. 

 

Operate the access controller within the rated range of power input and output. 

 

Do not dissemble the access controller. 

 

Transport, use and store the access controller under the allowed humidity and temperature 

conditions. 

Electrical Safety 

 

Improper battery use might result in fire, explosion, or inflammation. 

 

When replacing battery, make sure the same model is used. 

 

Use  the  recommended  power  cables  in  the  region  and  conform  to  the  rated  power 

specification. 

 

Use  the  power  adapter  provided  with  the  access  controller;  otherwise,  it  might  result  in 

people injury and device damage. 

 

The power source shall conform to the requirement of the Safety Extra Low Voltage (SELV) 

standard,  and  supply  power  with  rated  voltage  which  conforms  to  Limited  power  Source 

requirement according to IEC60950-1. Please note that the power supply requirement is 

subject to the device label. 

 

Connect the device (I-type structure) to the power socket with protective earthing. 

 

The appliance coupler is a disconnection device. When using the coupler, keep the angle 

for easy operation. 

Summary of Contents for DHI-ASI7213X-T

Page 1: ...Face Recognition Access Controller Quick Start Guide V1 0 0...

Page 2: ...he paper manual CD ROM QR code or our official website If there is inconsistency between paper manual and the electronic version the electronic version shall prevail All the designs and software are s...

Page 3: ...the ventilation of the access controller Operate the access controller within the rated range of power input and output Do not dissemble the access controller Transport use and store the access contr...

Page 4: ...s 1 2 Installation 6 Installation Notes 6 2 1 Cable Connections 7 2 2 Installation 8 2 3 3 System Operation 12 Initialization 12 3 1 Adding New Users 12 3 2 4 Web Operation 15 Notes of Face Recording...

Page 5: ...1 6 The 7 inch access controller has two models model A and model B See Figure 1 1 to Figure 1 4 7 Inch Access Controller Dimensions and components of model A 1 mm inch Figure 1 1 Table 1 1 Component...

Page 6: ...inch Figure 1 2 Table 1 2 Component description 2 No Name No Name 1 USB port 6 IR light 2 MIC 7 Dual camera 3 White fill light 8 Phototransistor 4 Display 9 Cable entry 5 Card swiping area 10 Fingerp...

Page 7: ...a 6 Display 3 White fill light 7 Card swiping area 4 IR light Dimensions and components of model B 2 mm inch Figure 1 4 Table 1 4 Component description 4 No Name No Name 1 MIC 5 Phototransistor 2 Dual...

Page 8: ...ponents 4 Dimensions and components 1 mm inch Figure 1 5 Table 1 5 Component description 1 No Name No Name 1 IR light 6 Phototransistor 2 MIC 7 Dual camera 3 White fill light 8 Cable entry 4 Display 5...

Page 9: ...imensions and components 2 mm inch Figure 1 6 Table 1 6 Component description 2 No Name No Name 1 IR light 6 Phototransistor 2 MIC 7 Dual camera 3 White fill light 8 Cable entry 4 Display 9 Fingerprin...

Page 10: ...ation should be no less than 100Lux It is recommended that the device is installed indoors at least 3 meters away from windows and doors and 2 meters away from lights Avoid back light and direct sunli...

Page 11: ...security module is enabled in Function Security Module If the security module is enabled you need to purchase access control security module separately The security module needs separate power supply...

Page 12: ...3 Ethernet port 4 Ethernet port only supported by 7 inch model B access controllers 5 USB port only supported by 7 inch model B access controllers Installation 2 3 Installation method of model A and...

Page 13: ...Installation 9 Installation height Figure 2 5 Installation diagram 1 Figure 2 6...

Page 14: ...in the bracket Fix the bracket on the wall by installing the expansion screws into the six bracket Step 2 installation holes Connect cables for access controller Step 3 See 2 2 Cable Connections Hang...

Page 15: ...Installation 11 Applying silicon sealant Figure 2 8...

Page 16: ...onsist of 8 to 32 non blank characters and contain at least two types of characters among upper case lower case number and special character excluding For access controller without touch screen initia...

Page 17: ...ecorded and one fingerprint needs to be verified three times You can enable the Duress FP function under each fingerprint and only one of the three fingerprints can be the duress fingerprint Alarms wi...

Page 18: ...set a period in which the user can unlock the door For detailed period settings see the user manual Holiday Plan You can set a holiday plan in which the user can unlock the door For detailed holiday p...

Page 19: ...p 1 controller in the address bar and then press Enter Make sure that the computer used to log in to the web is in the same LAN with the device 7 inch model B access controllers of have dual NICs The...

Page 20: ...ep your face clean Keep the device at least two meters away from light source and at least three meters away from windows or doors otherwise backlight direct sunlight might influence face recognition...

Page 21: ...might be influenced Appendix figure 1 2 Appropriate face position Requirements of Faces Make sure that the face is clean and forehead is not covered by hair Do not wear glasses hats heavy beards or ot...

Page 22: ...n importing face images through the management platform make sure that image resolution is within the range 150 300 600 1200 image pixels are more than 500 500 image size is less than 75KB and image n...

Page 23: ...print is centered on the recording area Do not put the fingerprint sensor at places with intense light high temperature and high humidity If your fingerprints are worn or are unclear try other unlock...

Page 24: ...Fingerprint Record Instruction 20 Appendix figure 2 2 Correct finger pressing Incorrect method Appendix figure 2 3 Wrong finger pressing...

Page 25: ...ed to enable the auto check for updates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client softwar...

Page 26: ...llowing services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMTP Choose TLS to access mailbox server FTP Choose SFTP and set up strong passwords AP hotspot...

Page 27: ...s If there are no communication requirements between two sub networks it is suggested to use VLAN network GAP and other technologies to partition the network so as to achieve the network isolation eff...